beautypg.com

0 gallon air tank & plumbing – VIAIR Ultra-Light Duty OBA User Manual

Page 3

background image

USER MANUAL

ULTRA-LIGHT DUTY ONBOARD AIR SYSTEM

1.0 GALLON AIR TANK & PLUMBING

Your 1.0 gallon air tank comes with four 1/4” NPT port openings. To insure safe & trouble-free use of your air

tank, install the drain cock and a safety pressure relief valve. (See Figure 1)

Tank Fittings:

Install supplied fittings for the air tank in areas where they are most appropriate for your installation using

thread sealant or Teflon tape. Make sure that the safety valve is installed in the top of the tank, and that the

drain cock is installed in the lowest position of the tank Be sure that all fittings are accessible since you may

have to plumb each fitting as needed to utilize the air tank properly.

IMPORTANT:

- Tank is rated for 150 PSI maximum working pressure.

- Tank is NOT to be used as a breathing device.

- Bleed pressure from tank before servicing or adding attachments.

- Use only attachments or tools rated for 150 PSI working pressure or less.

CAUTION! DO NOT PRESSURIZE YOUR TANK UNTIL YOU HAVE INSTALLED

ALL NECESSARY PORT FITTINGS AND ACCESSORIES.

- Apply sealant to threads of fittings prior to assembly and tighten each part with a wrench.

- Do not over tighten if your port fittings are made from brass, since brass threads can be stripped.

- Always release air from tank before servicing.

WARNING: FAILURE TO DRAIN TANK AND REMOVE CONDENSATION

WILL CAUSE TANK TO RUST PREMATURELY.

- To remove accumulated condensation inside the tank, bleed pressure from tank until pressure

is approximately 5 PSI to 20 PSI using drain cock.

- Drain water from tank by opening the drain cock drain valve and close after draining tank.

- If drain cock valve is plugged, release all air pressure from tank, remove drain valve and clean, then reinstall.

IMPORTANT: Replace air tank 2 to 5 years from date air tank was first used.

Adhering to air tank draining guidelines will prolong the life of your air tank.

PLEASE NOTE: RUSTED TANKS CAN FAIL CAUSING EXPLOSIONS OR FATAL INJURIES.

Discard tank immediately if tank is rusted.

SAFETY VALVE: When using a safety pressure relief valve, point the safety pressure relief valve away

from your body when releasing air. Use the pull ring on the safety relief valve to vent pressure from the

tank before servicing.

P/N 10000

OBA PLUMBING DIAGRAM

15 Edelman

Irvine, CA 92618

949-585-0011

www.viaircorp.com

1.0

Gallon

Tank

Drain

Cock

Leader Hose

From Compressor

Pressure

Switch

Safety

Valve

T-Fitting

T-Fitting

BSP Adapters

(For Air Lockers)

Compression

Fitting

OR

Rev.1

Plumbing Diagram:

(Figure 1)