• Part No. 25058 / 250C-IG-24V Compressor Kit
(CE Spec.)
Motor Voltage:
24 Volts
Max. Current Consumption:
5 Amps
Motor Type:
Permanent Magnetic
Horsepower:
1/4
Max. Working Pressure:
150 PSI
Max. Duty Cycle (@ 72°F & 100 PSI):
100%
Minutes On/Off (@ 72°F & 100 PSI):
Continuous
Max. Restart Pressure:
150 PSI
Max. Ambient Temperature:
158°F
Min. Ambient Temperature:
-40°F
Auto. Reset Thermal Protection:
Yes
Dimensions:
7.6”L x 4”W x 6.75H”
Net Weight:
6.75 Lbs.
COMPRESSOR APPLICATION GUIDE
To ensure that you get the highest level of satisfaction from your compressor’s performance, refer to
information below:
VIAIR COMPRESSOR REFERENCE CHART
COMPRESSOR SERIES
DUTY CYCLE
WORKING PRESSURE
100 SERIES
15%
130 PSI
275 SERIES
25%
150 PSI
280 SERIES
30%
150 PSI
325 SERIES
33%
150 PSI
350 SERIES
100%
150 PSI
380 SERIES
100%
200 PSI
400 SERIES
33%
150 PSI
450 SERIES
100%
150 PSI
480 SERIES
100%
200 PSI
ABOUT COMPRESSOR DUTY CYCLE:
Compressor Duty Cycle refers to amount of time a compressor can be operated in a given time
period, at 100 PSI and at a standard ambient temperature of 72°F. Duty Cycle is commonly
expressed in percentile as:
Compressor on Time/ (Compressor on Time + Off Time) %
As an example, a compressor that is rated for 25% duty cycle means that compressor can be
operated at:
100 PSI @ 72°F for 10 Minutes ON and 30 Minutes OFF
10 Min. On / (10 Min. On + 30 Min. Off) = 10 Min. / 40 Min.
=25% Duty Cycle
DUTY CYCLE REFERENCE CHART
DUTY CYCLE @100PSI / 72°F
MINUTES ON / OFF
15%
6 Min. On / 34 Min. Off
20%
8 Min. On / 32 Min. Off
25%
10 Min. On / 30 Min. Off
30%
13 Min. On / 30 Min. Off
33%
15 Min. On / 30 Min. Off
100%
Continuous Duty
USER MANUAL