beautypg.com

Current transformer test set, Specifications, Vanguard instruments company – Vanguard EZCT User Manual

Page 3: Pc printer output ▼ thermal printer output, Reliability through instrumentation

background image

the Tedious Procedure of Current-Transformer Testing
with Vanguard’s EZCT

TM

Current Transformer Test Set

Rugged 16-Key

Membrane Keypad

Connector for

H Terminals

Test Voltage

Selector

Test Voltage

Presence Indicator

RS-232C

Interface

4.5-inch Wide

Thermal Printer

Back-lit LCD Screen

(20 characters by 4 lines)

USB

Interface

Connector for

X Terminals

Test Voltage

Control Knob

PC Printer Output

Thermal Printer Output

Portable current-transformer test set

16.8”W x 12.6”H x 12”D (42.7 cm x 32 cm x 26.9 cm); Weight: 55 lbs (25 Kg)

100 – 120 Vac or 200 – 240 Vac (factory pre-set), 50/60 Hz

ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1

0 – 50 Vac @ 2A max; 0 – 200 Vac @ 2A max; 0 – 1200 Vac @ 1.5A max (5 min on, 10 min off)

0 – 1,250 Vac; Accuracy: ±1.0% of reading, ±0.5 volt

0 – 10A; Accuracy: ±1.0% of reading, ±0.01A

0.8 – 99: ±0.5%, 100 – 999: ±1.0%, 1,000 – 5,000: ±2%

0 – 360 degrees; Accuracy: ±1.0 degree

Back-lit LCD Screen (20 characters by 4 lines); viewable in bright sunlight and low-light levels

Built-in 4.5-inch wide thermal printer

One RS-232C port, One USB port

Windows® XP/Vista-based software is included with purchase price

Stores 128 test records. Each test record may contain up to 10 excitation and ratio data sets

Stores 10 test header records

Designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards

Operating: -10˚ to 50˚ C (15˚F to +122˚ F); Storage: -30˚ C to 70˚ C (-22˚F to +158˚ F)

90% RH @ 40˚C (104˚F) non-condensing

2,000m (6,562 ft) to full safety specifications

One 20-foot X cable set, One 35-foot H cable set, power cord, One cable carrying duffel bag

Transportation case

One year on parts and labor

TYPE

PHYSICAL SPECIFICATIONS

INPUT POWER

MEASUREMENT METHOD

OUTPUT TEST VOLTAGES

VOLTAGE READING RANGE

CURRENT READING RANGE

CURRENT-RATIO RANGE

PHASE ANGLE MEASUREMENT

DISPLAY

PRINTER

COMPUTER INTERFACES

PC SOFTWARE

INTERNAL TEST RECORD STORAGE

INTERNAL TEST HEADER STORAGE

SAFETY

ENVIRONMENT

HUMIDITY

ALTITUDE

CABLES

OPTIONS

WARRANTY

Vanguard Instruments Company

Reliability Through Instrumentation

SPECIFICATIONS

Note: The above specifications are valid at nominal voltage and ambient temperature of +25

°

C (+77

°

F). Specifications are subject to change without notice.

RVFeb10