beautypg.com

Maintenance specifications replacement parts – TIF 8900 Combustible Gas Detector User Manual

Page 7

background image

BATTERY PERFORMANCE

The unit is equipped with a low battery indicator. When the instrument is turned on, the indicator
the indicator should be lit. If the light is not on, then recharge the batteries, using the recharger.

NOTE: Each battery in your TIF8900 is an unique Ni-Cad cell. Use only TIF replacement batteries

recomended in the replacement parts. Any other typical Ni-Cad battery will not function

correctlly.

To install batteries, unscrew and remove the battery cover (see figure on page 3). Be sure to
install batteries as indicated in the battery compartment. Before operating the instrument, new
batteries must be initially charged for 24 hours.

TO RECHARGE BATTERIES

With the tool switch off, plug your recharger into the jack on the back of the instrument and plug
it into an electrical outlet in a non-hazardous area; See Warnings and Cautions on p.4.

For the SAFT and NEA Ni-Cad batteries:

Two 2.4V/0.75 ampere hour

Continuous Operation Time:

Approximately 4 hours

Power Supply:

4.8V; Ni-Cad Rechargeable batteries

Sensitivity:

Variable, as low as 5ppm (gasoline)

Operating Temperature Range:

32°F to 125°F (0°C to 52°C)

Duty Cycle:

Continuous; no limitation

Response Time:

Instantaneous

Warm-Up Time:

Approximately 30 seconds

Weight:

16 ounces (450 grams)

Dimensions:

8” x 3” x 1.8” (20.3 x 7.6 x 4.6 cm)

Probe Length:

15” (38 cm)

MAINTENANCE

SPECIFICATIONS

REPLACEMENT PARTS

6

• TIF8801: Combustible Gas Sensor
• TIF8803A: 115V Battery Charger
• TIF8805: 12V cigarette lighter recharger

• TIF8806A: Rechargable Ni-Cad Battery pack
• ATP-7038: Carrying case
• 527690RED: Battery cover