beautypg.com

Connecting to power, Redundant dc terminal block power inputs, Onnecting to – LevelOne IES-0820 User Manual

Page 10: Ower

background image

IES-0820 User Manual

Page 9

Connecting to Power

Redundant DC Terminal Block Power Inputs or 12VDC DC Jack (Optional)

Redundant DC Terminal Block Power Inputs

There are two pairs of power inputs can be used to power up this device. You need to have

two power inputs connected to run the device, but the FAULT LED indicator will light up to

remind that the power redundant system functions abnormal in case either PWR1 or PWR2

is dead. This device, however, continues working normally even fault LED indicator lights
up.

Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and

then plug it into a standard DC outlet.


Step 2: Disconnect the power cord if you want to shut down the switch.

Field Wiring Terminal: Use Copper Conductors Only, 60/75℃, 12-24 AWG torque value 7

lb-in.

Te

rmin

al

B

lo

ck

PW1

+

10 – 48VDC

Power Ground

PW2

+

10 – 48VDC

Power Ground

Earth Ground

Relay Output

1A @ 24VDC

1. The relay contact opens if Power1 or Power2 falls

2. The relay contact opens if the Port Link is broken

(When Link Down Detection is enabled)