beautypg.com

Jackco Model 842 User Manual

Page 4

background image

AIR REMOVAL

Removing air from the hydraulic system will help the cylinder to advance and retract smoothly.

Pump with Single-Acting Cylinder

• Position pump at higher elevation than cylinder.

• Position cylinder with plunger end down (up if using pull cylinder)

• Operate pump to fully extend the cylinder (retract if using pull cylinder)

• Depress release valve to retract cylinder (extend if a pull cylinder). This will force the trapped

air to move up to the pump reservoir.

• Repeat the above steps as necessary.

• Add oil if necessary.

• Return vent/fill cap to operating position.

How to fill the reservoir

1. Disconnect hydraulic coupler from application, remove air supply from pump.

2. Remove the vent /oil filler plug.

3. Fill reservoir to within ½ inch of the opening.

4. Wipe off any spilled fluid and install oil filler plug.

NOTE:

Use only quality hydraulic fluid. Never use brake fluid, transmission fluid, motor oil

etc. Use of other than quality hydraulic oil will void the warranty and damage the

equipment.

AIR SUPPLY

• To obtain maximum performance and rated hydraulic pressure, air pressure should be 100 psi

minimum.

• To insure trouble-free performance, your air supply equipment should be equipped with an air

filter/dryer and the compressor tank should be drained of water everyday.

LUBRICATION

• To insure long service life, add a few drops of # 30 oil into the air inlet once a week.

MAINTENANCE

Use only recommended JACKCO hydraulic oil with theses pumps to promote long pump life and

protect your warranty. Contact your JACKCO representative for more information on these products

and their applications.

KEEPING OIL LINES CLEAN

When coupler halves are disconnected, always screw on dust caps. Use every precaution to guard

unit against entrance of dirt because foreign matter may cause pump, cylinder or valve failure.

CHANGING THE OIL

• Drain all oil and refill with clean JACKCO hydraulic oil every 12 months, if pump is used in dirty

environments, change the oil more often.

• Remove vent/fill cap or plug from reservoir

• Tilt pump to drain out old oil.