beautypg.com

Probes – Agilent Technologies 54600-Series User Manual

Page 12

background image

12

Probes

To get the most out of your scope,
you need the right probes and
accessories for your particular
application. That's why Agilent
Technologies offers a complete
family of innovative probes and
54600-Series scopes. For more
comprehensive information,
please see the Agilent
54600-Series Oscilloscopes
Probes and Accessories
data sheet (Agilent publication
number 5968-8153). You can get a
copy by calling 1-800-452-4844 or
by visiting our website at:
www.agilent.com/find/mso

Agilent Passive Probes Selection Guide

10070C

10073C (shipped

10074C (shipped

10076A

N2771A

with 54640-Series)

with 54620-Series)

high-voltage probe

high-voltage probe

Probe Bandwidth

20 MHz

500 MHz

150 MHz

250 MHz

50 MHz

Probe Risetime (Calculated)

< 17.5 ns

< 700 ps

< 2.33 ns

< 1.4 ns

< 7 ns

Attenuation Ratio

1:1

10:1

10:1

100:1

1000:1

Input Resistance

1 M

2.2 M

10 M

66.7 M

100 M

(when terminated into 1 M

)

Input Capacitance

Approx. 70 pF

Approx. 12 pF

Approx. 15 pF

Approx. 3 pF

Approx. 1 pF

Maximum Input

400 Vpk CAT I

500 Vpk CAT I

500 Vpk CAT I

4000 Vpk

15 kV dc, 10 kVrms

(dc + peak ac)

(mains isolated)

(mains isolated)

(mains isolated)

30 kV dc + peak ac

400 Vpk CAT II

400 Vpk CAT II

400 Vpk CAT II

(post receptacle

(post receptacle

(post receptacle

mains)

mains)

mains)

Compensation Range

None

6 - 15 pF

9 - 17 pF

6 - 20 pF

7 - 25 pF

Probe Sense

No

Yes

Yes

Yes

No

Current Probes

Description

1146A

100 kHz current probe, ac/dc

N2774A

50 MHz current probe, ac/dc

N2775A

power supply for N2774A

Differential Probes

Description

N2772A

20 MHz differential probe

N2773A

Differential probe power supply