beautypg.com

Robinair 15434 User Manual

Operating manual, Vacumaster pump specifications, Important

background image

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Operating
Manual

VacuMaster Pump Specifications

Free Air Displacement

4 CFM

Stages

2

Motor Speed

1725 RPM

Voltage +10%

115V 60 HZ

Factory Micron Rating

20 microns

Approximate Oil Capacity

13 oz.

Weight

29 lbs.

Width

5

5

/

8

in.

Height

9

3

/

4

in.

Length

15 in.

Intake

1

/

2

” Acme

and

1

/

4

” Flare

Min. Starting Temp.
(at 90% Voltage)

32

o

F

Motor Size

1

/

3

hp

Capacitor Start

Operating Temp.

155

o

F

Note:

1. All motors are internally protected (automatic reset).

2. Operating temperatures are typical for normal operating

conditions.

U.S Patents: 4,523,897; 5,209,653. Other U.S. and Foreign Patents Pending.

Due to ongoing product improvements, we reserve the right to change design,

specifications and materials without notice.

SPX Corporation
655 Eisenhower Drive
Owatonna, MN 55060-0995 USA
Technical Services: 1-800-822-5561
Fax: 1-800-822-7805
Customer Service: 1-800-533-6127
Fax: 1-800-322-2890
Web Site: www.robinair. com

115247 (Rev. B 04/14/03)

CoolTech Pump Manual 15434

© SPX Corporation

IMPORTANT

Warranty Registration Card

FOLD ON LINE AND TAPE TO SEAL. DO NOT STAPLE.

Attn: Robinair Marketing

SPX Corporation

655 Eisenhower Drive

Owatonna, MN 55060-0995

BUSINESS REPL Y

MAIL

FIRST CLASS

PERMIT NO. 72

OWATONNA, MN

POSTAGE WILL BE PAID BY ADDRESSEE

NO POSTAGE

NECESSARY

IF MAILED

IN THE

UNITED STATES

High Performance Vacuum Pump

Model 15434

For use with refrigerants

R-12, R-22, R-500, R-502, or R-134a