Aerobell Copes - Operation
ELECTRODE REMOVAL
PROCEDURE FOR OPTIONAL
DIRECT CHARGING METHOD
-REFER TO FIGURE 8
1.
Verify that high voltage is OFF. The
high voltage must be turned OFF before
performing any maintenance.
2.
Remove item 7 (13521-03, compression nut)
and high voltage cable from port marked
HV.
3.
Remove item 22i (13521-03, compression nut)
and ground cable from port marked GND.
4.
Remove item 14 (14061-02, conductive foam
insert), item 13 (76562-00, spring loaded
contact pin screw assembly), item 12 (75841-
00, high voltage cable support tube) and item
9 (LSOR0007-06, O-Ring) from port marked
HV.
5.
Remove item 5 (Qty-6, 75847-00, electrode
body retaining nuts) and item 6 (Qty-6, 76719-
00, electrode body assemblies).
6.
Remove item 3 (Qty-20, M5 x 40mm long,
slotted fillister head screws) and item 4 (Qty-
5, 75854-02, 90
° connector electrode body
assembly.) Items 3 and 4 (marked “B”) must
be removed prior to removing items 3 and
15 (marked “A”).
7.
Remove item 3 (Qty-4, M5 x 40mm long,
slotted fillister head screws) and item 15
(75854-01, 90
° connector electrode body
assembly.) Unit damage may occur if items
3 and 15 (marked “A”) are removed prior to
disassembly of items 9, 12, 13 and 14 (marked
“C”) and items 3 and 4 (marked “B”).
8.
Install item 9 (LSOR0007-06, O-Ring), item 12
(75841-00, high voltage cable support tube)
and item 7 (13521-03, compression nut) into
port marked HV.
9.
Install 73033-20F, 1/4-28 x 5/8 long nylon
socket head cap screw (not shown), into item
12 (75841-00, high voltage cable support
tube). Torque screw to 3-5 inch pounds.
10.
Install 1/4 dia. x 3" long nylon rod (non-
conductive) material (not shown) into item 12
(75841-00, high voltage cable support tube)
and tighten item 7 (13521-03, compression
nut).
11.
Install S10364-00, (Qty-6, 90
° connector port
cap, not shown), LSOR0007-05, (Qty-6, o-ring,
not shown) and item 3 (Qty-24, M5 x 40mm,
long slotted fillister head screws) in ports
marked A and B. Torque screws to 3-5 inch
pounds. Unit damage may occur if screws
are over torqued.
12.
Install high voltage cable into port marked
GND and tighten item 22i (13521-03,
compression nut).
16
COATING MATERIAL
CONDUCTIVITY
The Aerobell Copes can be used with a full range of
conductive coatings including solvent-borne and
waterborne materials. Charging methods include:
• Indirect charge for use with waterborne, grounded
fluid systems. The fluid system, including the
applicator, are connected to ground potential and
voltage is applied to the external electrodes. (See
Figure 8.)
• Direct charge for use with solventborne, grounded
fluid systems with electrodes removed. The fluid
system is connected to ground potential and
voltage is applied to the applicator. (See Figure
8.)
• Direct charge for use with waterborne, isolated fluid
systems with electrodes removed. The fluid system
is isolated from ground potential and voltage is
applied to the applicator. (See Figure 8.)
LN-9230-00.1