Section 1 - General Specifications & Hazards
QUESTIONS?... Contact Customer Service at 1-800-753-1601 M-F 8:00 am- 4:15 pm CST
6
DHI-300 FRONT
Section 14 - Troubleshooting
Visit our website at: www.lanair.com
47
DIMENSIONS:
DHI-300
Height: 61”
Width: 43”
Depth: 47”
Weight: 370 LBS
FIRING CAPACITIES:
DHI-300
Nozzle @ 1.86 gallons/hour, No. 2 fuel oil
Symptom
Possible Cause
Corrective Action
A. Burner will not start
1. Main electrical power
1. Reset breaker
circuit breaker tripped
2. Service disconnect
2. Turn switch on or
switch off or fuse blown
replace fuse
3. Thermostat turned down/
3. Turn thermostat up,
improperly installed/
check wires/test
defective
components/replace
4. Oil primary safety
4. Reset/test components,
tripped/defective
replace if needed
5. Too much light showing
5. Eliminate light to cad cell
on cad cell/defective
Test component
B. Burner attempts to fire,
1. Low oil in supply tank or
1. Fill tank, or drain and
but does not establish a
contaminated fuel
clean tank
flame
2. Plugged or worn nozzle
2. Clean or replace
3. Fuel pressure gauge
3. See section 6, Page 17
fluctuating/pumping system
4. Pre-heater switch is turned off
4. Turn switch on or test
or defective, or defective
switch and cartridge heater
cartridge heater
5. Transformer/electrodes not
5. Test transformer/look
sparking
for shorts & repair
Replace electrodes/
transformer
6. No air pressure/defective
6. Turn compressor on/test
regulator/defective solenoid
regulator/solenoid. Replace
defective components
7. Water in air system
7. Clean air pre-heater and
drain water from system
8. Combustion blower not
8. See flame adjustment
properly adjusted or
pages 29-31.
defective
Replace blower
9. Improper draft
9. Check draft see page 15.
Make sure chimney is
properly installed
10. Plugged heat exchanger,
10. Clean heater including
or chimney
manifold, chimney