KISAE MW 1204 Power Inverter 400 User Manual
Page 8

Page 8
Following run time is an estimate based on using a 12V-120AH battery bank for reference. Actual
run time may vary.
Load
Consumption
Estimate Run time
Cordless Phone
5W
150 hrs
Clock/Radio 8W
100
hrs
Table Lamp
40W/60W
27 hrs/ 18 hrs
Freezer (8.8 cu. ft.)
80W
15 hrs
20” LCD TV
100W
11.5 hrs
Sump Pump (1/2 hp)
350W
Not applicable (surge too high)
5. TROUBLESHOOTING
To trouble shoot the unit, please note the error code display on the main unit and review the
“Understanding the Error Codes” in section 4.
Problem Symptom
Solution
No AC output and
‘Power’ indicator is
off.
The unit is off
Turn unit ON using the toggle switch
No power to inverter
Check fuse or the Disconnect switch (if
installed) is either blown or turn OFF
No AC output. ‘Fault’
indicator is ON
Unit detect fault and has
shutdown
Verify the error condition and make
correction and reset unit
Products connected
to unit malfunction or
overheat
Products connected to unit
do not accept modified
sine wave output
Products are not compatible with the
modified sine wave output generated by
the KISAE Power Inverter. See “AC
Load on Power Inverter” in Section 4