beautypg.com

Commercial gas water heaters – A.O. Smith BTN 120-40D User Manual

Page 3

background image

®

Commercial Gas Water Heaters

Revised October 2012

PG 3 OF 4

www.hotwater.com

AOSCG10500

ROUGH-IN DIMENSIONS

SIDE VIEW OF BTN

Models 120-400

TOP VIEW OF BTN

Clearance to Combustibles

Clearance to Non-Combustibles

Model

Sides & Rear

Top Cover

Sides & Rear

Top Cover

BTN120

1”

12”

0”

12”

BTN154

1”

12”

0”

12”

BTN180

1”

12”

0”

12”

BTN199C

2”

12”

2”

12”

BTN199

1”

12”

0”

12”

BTN200(A)

1”

12”

0”

12”

BTN250(A)

2”

12”

0”

12”

BTN275(A)

2”

12”

0”

12”

BTN310(A)

2”

12”

0”

12”

BTN366(A)

3”

12”

0”

12”

BTN400(A)

3”

12”

0”

12”

Water Connections in Inches

Inlet

Outlet

Models

Top

Front

Back

Top

Front

Back

BTN120

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

BTN154

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

BTN180

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

BTN199C

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

BTN199

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

BTN200(A)

1 1/2

1 1/2

2

1 1/2

1 1/2

2

BTN250(A)

1 1/2

1 1/2

2

1 1/2

1 1/2

2

BTN275(A)

1 1/2

1 1/2

2

1 1/2

1 1/2

2

BTN310(A)

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

BTN366(A)

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

BTN400(A)

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

1 1/2

Gas Pressure Requirements

Natural Gas

Max. Supply Pressure

14” w.c.

Min. Supply Pressure

5.2” w.c.

Manifold Pressure

3.5” w.c.

Electrical Specifications

Volts

Amps

BTN

120VAC

5.0

251325_AOSCG10500.indd 3

251325_AOSCG10500.indd 3

11/7/12 1:50 PM

11/7/12 1:50 PM