Gas and steam – American Dryer Corp. ML-82 III User Manual

Page 21

background image

113344 - 9

www.amdry.com

17

* Contact factory for 3-wire system.

8/4/08

IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In the

case of 208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically VOID THE
WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or

obligation.

3. Electrical Connections

NOTE: A wire diagram is located in the front electrical control box for connection data.

NOTE: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.

Gas and Steam

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT:

NOTES: A.

B.


C.

208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.

When fuses are used they must be dual element, time delay, current

limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value,
by applying either local and/or National Electrical Codes to listed

appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY.

For others, calculate/verify correct breaker size according to appliance

amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

VOLTAGE

PHASE

WIRE

SERVICE

APPROX.

AMP DRAW

CIRCUIT

BREAKER

60 Hz

50 Hz

208

3

14.4

20

240

3

14.0

15.9

20

380-400

4*

8.4

15

416

4*

8.7

15

440

4*

8.6

15

460/480

3

7.5

15

2. Electrical Service Specifications