en

glowing materials. Do not vacuum any moist
or liquid substances or highly inflammable or
explosive substances or gases.

- The brush and tubes must not be brought to

head height whilst the machine is operational.

- Only clean the brush with a dry or damp

cloth. Never immerse it in water.

- Do not expose the brush to the weather or

any heat sources.

- The socket on the vacuum cleaner may only

be used for the mounted unit. Disconnect
the mains plug before connecting any
mounted units.

- Do not reach into the rotating brush roller.
- Do not move the rotating brush roller over

the mains lead.

- After completing the vacuuming work, dis

connect the machine from the mains supply.

First of all unfold the last page containing
the illustrations.

Applications

The ”ELECTROMATIC PLUS” brush is designed
to vacuum and brush carpets with a vacuum
cleaner. It removes dust, fluff, threads and hairs
particularly thoroughly. If the carpet pile has
been flattened, the brush will produce a visible
loosening of the pile. The brush can also be
used on hard floors.
Important: Do not move the brush into the vici-
nity or long hair, scarves, ties, etc.

Notes

Do not move the rotating brush roller over the
mains lead. When the brush is rotating, do not
leave the machine in one place on the carpet or
it may damage the pile.
Wool velour carpets, particularly those with a
loose pile, should only be cleaned with the
mounted brush unit at long intervals.

To use the brush

Assembly

Fit the ”ELECTROMATIC PLUS” brush like a
suction tube. Connect the lead (2) into the
socket on the vacuum cleaner (Fig. 1).
When you switch on the vacuum cleaner, the
”ELECTROMATIC PLUS” brush will also be
switched on.

Servicing

If the brush roller becomes blocked during clea-
ning by vacuuming foreign bodies or due to
frayed carpet thread wrapping around it, the
motor will shut down automatically.
Before competing any servicing work, switch off
the vacuum cleaner and disconnect its mains
plug.
The ”ELECTROMATIC PLUS” brush will cut in
again when the blockage has been removed
after it has waited for one minute and it has
been reconnected to the power supply.

To remove threads
wrapped around the roller

Threads and hairs wrapped around the roller
can be removed easily by cutting them with a
pair of scissors (Fig. 3) and then vacuuming
them with a gap nozzle (Fig. 4).

5100 401 262 A 02.04.2013 14:25 Uhr Seite 4