beautypg.com

Fuel flow/pressure (fp-5 and fp-5l) wiring diagram – Electronics International FP-5L User Manual

Page 13

background image

Fuel Flow/Pressure (FP-5 and FP-5L)

Wiring Diagram

11

6' Red Wire
6' Black Wire

6' White Wire

Red
Black
White

AUX Channel Input Lines. See the Installation
Instructions for the approprIate Functional Module.

White/Red Wire
White/Yel Wire
White Wire

Circular Connector

3' Display Mode Indicator LED Dimming Line, connects to Panel Light
Rheostat. 12/24 volts dims the Display Mode LEDs.

3' (

Optional) External Warning Control Line. Can be connected to a

relay to control an external light, buzzer, etc. Grounds when Red
Warning Light is on. Current must be limited to 2/10 amp maximum.

3' Backlight Control Line, connects to 24 Volt Bus. Connect to ground
for 12 Volt System.

3' Backlight Control Line, connects to 12 Volt Bus. 12 volts turns on
the digital display backlight.

3' Ground Lead, connects to Ground.

3' Power Lead, connects to 12 or 24 Volt Bus.

White/Yel

Black

Red

White/

Brwn

White/Red

White/

Orng

Do not use screws

longer than 1/2" (4 ea.).

2ea - 3' (

FP-5L Only) RS-232/422 Serial Lines. See the FP-5 and FP-5L

Circular Connector data on page 14.

Wire Harness

Connect the same color of 6' wires from the unit
to the Fuel Flow Transducer. If connectors are
removed, double wires and tightly crimp on new
connectors.

Fuel Flow
Transducer

Note: For a
carburetor with a
fuel return line
see next page.

Wht/Grn

Wht/Blu

Rev. I: 7/2/02