beautypg.com

Unpacking description, Electrical specifications, General safety information danger – World Dryer Airforce J & J4 User Manual

Page 2: Danger, Warning, Caution, Table 1

background image

2

Unpacking

Description

World warm air hand dryer, powered by universal brush motor, delivers 1100 Watts of drying power. This hand dryer runs

on 120 Volt or 208-240 Volt AC electrical supply depending on model. An infrared sensor is used to automatically turn the

dryer on and off. This model is intended for use in commercial, industrial, office and public facility environments.

Electrical Specifications

Table 1

General Safety Information

DANGER

Failure to disconnect the power source before installation or servicing can result in serious

injury or death from electric shock.

• Always disconnect the power source before servicing or installing the hand dryer.

DANGER

Failure to properly ground this unit could result in severe electrical shock and/or death.

• This hand dryer must be properly grounded (Earthed) for safe operation. An identified ground connection point

is supplied on the hand dryer’s wall base.

• We recommend GFCI protection in wet or damp locations or as required by local code.

WARNING

Risk of fire, personal injury or property damage are possible if local codes, or safety

recommendations are not followed.

• Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed. See

Table 1 – Electrical Specifications.

• Connect the hand dryer to the nearest suitable distribution panel. The fixed wiring must include a disconnection

means complying with local wiring codes.

• To limit a voltage drop, and insure efficient operation, use No. 12 AWG (4 mm2) wire or larger as required by

local electrical codes.

• Always connect to a branch circuit with circuit breaker or fuse protection with an electrical rating greater than the

model hand dryer’s rated amperage shown in Table 1 - Electrical Specifications.

• To avoid a hazard due to inadvertent resetting of the thermal cutout, the hand dryer must not be supplied

through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by

the utility.

• Each automatic model hand dryer must have a dedicated circuit.

• Route all field wiring away from moving parts within the hand dryer.

CAUTION

Improper mounting could result in personal injury or property damage.

• Follow the mounting height recommendations in Table 2.

• On a stud wall, one side of the hand dryer should be mounted to an existing stud.

1. Remove fuse or shut off power to the dryer at fuse box.

2. With Allen wrench supplied with dryer, turn clockwise two Allen screws from bottom side of dryer case.

3. Remove dryer cover.

Models

Type

Electrical Input

Rated Amperage Rated Watts Certifications

J-XXX

Automatic

120 VAC, 50/60Hz

9.6A

1100

UL, E320188

J4-XXX

Automatic

208-240 VAC, 50/60Hz

4.8A

1100

UL, E320188

This appliance is not intended for use by young children or persons with physical, sensory or mental disabilities

unless adequately supervised by a responsible person to ensure they can use the appliance safely. Young children

should be supervised to ensure they do not play with the appliance.