Unpacking
Description
World warm air hand dryer, powered by universal brush motor, delivers 1100 Watts of drying power. This hand dryer runs
on 120 Volt or 208-240 Volt AC electrical supply depending on model. An infrared sensor is used to automatically turn the
dryer on and off. This model is intended for use in commercial, industrial, office and public facility environments.
Electrical Specifications
Table 1
General Safety Information
DANGER
Failure to disconnect the power source before installation or servicing can result in serious
injury or death from electric shock.
• Always disconnect the power source before servicing or installing the hand dryer.
DANGER
Failure to properly ground this unit could result in severe electrical shock and/or death.
• This hand dryer must be properly grounded (Earthed) for safe operation. An identified ground connection point
is supplied on the hand dryer’s wall base.
• We recommend GFCI protection in wet or damp locations or as required by local code.
WARNING
Risk of fire, personal injury or property damage are possible if local codes, or safety
recommendations are not followed.
• Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed. See
Table 1 – Electrical Specifications.
• Connect the hand dryer to the nearest suitable distribution panel. The fixed wiring must include a disconnection
means complying with local wiring codes.
• To limit a voltage drop, and insure efficient operation, use No. 12 AWG (4 mm2) wire or larger as required by
local electrical codes.
• Always connect to a branch circuit with circuit breaker or fuse protection with an electrical rating greater than the
model hand dryer’s rated amperage shown in Table 1 - Electrical Specifications.
• To avoid a hazard due to inadvertent resetting of the thermal cutout, the hand dryer must not be supplied
through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by
the utility.
• Each automatic model hand dryer must have a dedicated circuit.
• Route all field wiring away from moving parts within the hand dryer.
CAUTION
Improper mounting could result in personal injury or property damage.
• Follow the mounting height recommendations in Table 2.
• On a stud wall, one side of the hand dryer should be mounted to an existing stud.
1. Remove fuse or shut off power to the dryer at fuse box.
2. With Allen wrench supplied with dryer, turn clockwise two Allen screws from bottom side of dryer case.
3. Remove dryer cover.
Models
Type
Electrical Input
Rated Amperage Rated Watts Certifications
J-XXX
Automatic
120 VAC, 50/60Hz
9.6A
1100
UL, E320188
J4-XXX
Automatic
208-240 VAC, 50/60Hz
4.8A
1100
UL, E320188
This appliance is not intended for use by young children or persons with physical, sensory or mental disabilities
unless adequately supervised by a responsible person to ensure they can use the appliance safely. Young children