Installation, Adjusting dryer controls, Table 2 table 3 – World Dryer SMARTdri Series K48 User Manual
Page 4: Table 4
5
Installation
1. Disconnect the power source.
2. Using Table 2 to determine the recommended mounting height, select a mounting location for the hand dryer where
no reflective surfaces or objects (such as a hand basin) are directly under the infra-red sensor eye. The infra-red
sensor eye is visible from the bottom of the dryer and is located just inside the dryer’s nozzle area. The minimum
mounting distance from bottom of the dryer to a reflective surface is 18 in (46 cm). When two or more dryers are
installed, they should be spaced apart 24 in (61 cm)
3. Use the security hex key supplied to turn the cover mounting screws
clockwise to remove the cover from the dryer.
4. Place the hand dryer base on the wall at selected location and using the base as a template, mark locations for the 4
mounting bolt holes on the wall.
5. Fasten the base to the wall, using the type of bolts recommended in Table 3
6. Each dryer must have is own dedicated circuit.
7. Connect the dryer to the nearest suitable distribution panel.
8. Replace cover, turn screws
counter-clockwise making certain not to over-tighten.
IMPORTANT: Consult local and general regulations before performing dryer installation. Ensure that the
electrical network is not overloaded. Do not connect to a branch circuit rated less than the model hand
dryer’s rated amperage shown in Table 1 – Electrical Specifications.
Motor Setting
Power Usage (Watts)
Heater "OFF"
Heater “ON”*
Hi
800
1200
Med
575
975
Low
400
800
Recommended Mounting Heights from Floor to Dryer Bottom Edge
in. (cm.)
Men’s washrooms
46 (117)
Women’s washrooms
44 (112)
Children’s washrooms, ages 4-7
32 (81)
Children’s washrooms, ages 7-10
36 (91)
Children’s washrooms, ages 10-13
40 (102)
Children’s washrooms, ages 13-17
44 (112)
Handicap Mounting Height
37 (94)
Table 2
Table 3
Type of Wall
Type of Bolt
Minimum Bolt Length
Hollow Tile, Lath, Wall Board or Metal
1/4” (M6) screw Type or Wing Type
toggle Bolts
Dependent on wall
thickness
Cement, Brick, or Tile Covered Cement or Brick
1/4” (M6) Stud Type Expansion Bolts
3” (76mm)
Stud Wall with wood Backing
No 16 (M8) Wood Screws
23/4” (70mm)
Table 4
The hand dryer has adjustable controls for (3) levels
of operation – Hi, Med and Low. The dryer can be
operated with the heating element “ON” or “OFF”.
The dryer’s power usage for the range of operation is
shown in Table 4.
Note: The factory setting for the dryer
controls is motor “Hi” and heater “ON”.
Adjusting Dryer Controls
* Heating element wattage is 400W maximum.