Section 5: TROUBLESHOOTING

5.10 TROUBLESHOOTING

TABLE

Poor

Pumping

Speed

Poor

Vacuum

Loud

Unit

Possible Cause

Corrective Action

X

X

X

Damaged valves

Replace fl apper valves

X

X

X

Debris in valves

Remove debris and check for valve damage

X

X

X

Damaged gasket

Replace gasket

X

X

X

Loose head screw

Tighten head screw

X

X

X

Loose fi tting

Tighten fi tting

Section 6: SPECIFICATION

6.10 SPECIFICATION

CHART

Welch Model

2522

2534

Free Air Displacement

CFM (L/min.) @60Hz

0.76 (22)

1.20 (34)

M3 (L/min.) @50Hz

0.66 (19)

1.0 (28)

Maximum Continuous Pressure

PSIG (Pascal)

100

50

Maximum Vacuum

In.Hg. (Torr)

25.6 (110)

26.2 (950

Motor Horsepower

Horsepower

1/8

1/7

Tubing needed

I.D. in Inches

1/4

1/4

Weight lbs

11.7

11.7

(Kg.)

(5.3)

(5.3)

Catalog Number

Wired for 115V, 60Hz,1Phwith North American 115V Plug

2522B-01

2534B-01

Wired for 220V, 50Hz, 1Ph with European (Schuko) Plug

2522C-02

-

Wired for 230V, 60Hz, 1Ph with Cont. Euro 230V Plug

2522C-10

-

NOTE: *230V 60Hz Models have a maximum continuous pressure of 50PSIG (5x10

5

Pascal)

**50Hz models are provided with CE agency mark.