beautypg.com

Specifications, Operation, Remarks – Amcor ALTL -12 User Manual

Page 3: Important, Regulating the airflow direction

background image

10

3

Specifications

Model Number

ALTL-12,000E

ALTL-12,000EH

Cooling Capacity

12,000 BTU/hr

12,000 BTU/hr

Heating Capacity

N/A

12,000 BTU/hr

Power Consumption

950W / 8.4A

950W / 8.4A

Humidity Removal Capacity

65 Pts. / Day

65 Pts. / Day

Recommended room size*

Up to 400 sq. ft.

Up to 400 sq. ft.

Power Supply

115V / 60Hz / 1 Phase

115V / 60Hz / 1 Phase

Compressor

Rotary

Rotary

Refrigerant

R-22

R-22

Fan Speed

2

2

Timer

1-24 hours 1-24 hours

Temperature Set Range

62°F - 90°F

62°F - 90°F

Unit Weight

65 lbs.

68 lbs.

Dimensions

16"W x 17"D x 30"H

16"W x 17"D x 30"H

Working Temperature

Cooling: 62°F to 110°F

Cooling: 62°F to 110°F

Heating: 41°F to 81°F

REMARKS:

The cooling capacity of the unit may be affected by the height of the ceiling,
quality of insulation, number of windows, etc.

Operation

Turn the roller on the air vent to control
the airflow direction from the vertical louvers.

Move the air vent directly to adjust the
airflow direction from the horizontal louvers.

IMPORTANT!

• The compressor will start approximately 3 minutes after the unit is turned on (this will

help prolong the life of the compressor). After switching the unit off, please wait at least
3 minutes before turning the unit back on.

• The cooling system will switch off if the room temperature is lower than set. The fan, however, keeps

working at the set level. If the ambient temperature rises above the chosen temperature +/-5°F,

the cooling will resume.

• In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set

(the fan keeps working at the set level). When the room temperature drops 5°F below the chosen

temperature, heating will resume.

• This machine is equipped with an ANTI-FROST function. Sometimes, while using the heating function

during low temperatures, the heating will stop for a while to melt the internal frost. When this occurs,
wait for heating to resume.

• As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.

Regulating the Airflow Direction