beautypg.com

Product features and specifications – PSA LIFCO9 User Manual

Page 9

background image

2. Product Features and Specifications

Green,
Power LED

Red,

Alarm LED

Test / Reset

Button

WARNING: After seven (7) years from initial power up, this alarm
will “beep” every 30 seconds to indicate that it is time to replace
the alarm. Replace the alarm immediately! It will not detect CO in
this condition.

Model KN-COB-B-LS-UK (900-0233)

Temperature:
Operating Range: 40°F (4.4°C) to 100°F (37.8°C)

Humidity:
Operating range: 10-95% non-condensing

Audible Alarm:
85+ dB at 10’ @ 3.4±0.5 KHz pulsing alarm

Sensor:
Electrochemical

Power:
3-AA Batteries

Alarm Response Times:
30 ppm = no alarm in 120 minutes

50 ppm = Must alarm in 60-90 minutes

100 ppm = Must alarm in 10-40 minutes

300 ppm = must alarm within 3 minutes

2522-7216-00 (900-0233):_ 2011.10.21 5:10 PM Page 9