MIXING VALVE USAGE

Water (Potable) Heating: All models are considered suitable for
water (potable) heating only.

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a
temperature which will satisfy space heating, clothes washing, dish
washing, and other sanitizing needs can scald and permanently injure
you upon contact. Some people are more likely to be permanently
injured by hot water than others. These include the elderly, children,
the infi rm, or physically/mentally disabled. If anyone using hot water in
your home fi ts into one of these groups or if there is a local code or state
law requiring a certain temperature water at the hot water tap, then you
must take special precautions. In addition to using the lowest possible
temperature setting that satisfi es your hot water needs, a means such
as a mixing valve, should be used at the hot water taps used by these
people or at the water heater. Mixing valves are available from your local
plumbing contractor. Consult a Qualifi ed Installer or Service Agency.
Follow mixing valve manufacturer’s instructions for installation of the
valves. Before changing the factory setting on the thermostat, read the
“Temperature Regulation” section in this manual.

FACTS TO CONSIDER ABOUT THE LOCATION

Carefully choose an indoor location for the new water heater,
because the placement is a very important consideration for the

safety of the occupants in the building and for the most economical
use of the appliance.

Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed:

1. Select a location indoors as close as practical or centralized to

the water piping system as possible. The water heater should be
located in an area not subject to freezing temperatures.

2. Selected location must provide adequate clearances (4”/101.6 mm)

for servicing parts such as the thermostats, drain valve, and relief
valve. Adequate clearance for servicing this appliance should be
considered before installation, such as changing the anodes, etc.

LOCATING THE NEW WATER HEATER

FIGURE 2.

(152.4 mm)

DISCHARGE PIPE

(DO NOT PLUG)

(PROVIDE 6” (152.4 mm)

MAXIMUM AIR GAP BETWEEN

PIPE AND DRAIN.)