beautypg.com

Important, Manual reset hi-limit instructions – American Dryer Corp. Extended Side Panel AD-120ES II User Manual

Page 68

background image

64

SECTION XI

BURNER AND BASKET (TUMBLER)/LINT CHAMBER

MANUAL RESET HI-LIMIT INSTRUCTIONS

I M P O R T A N T

MANUAL RESET HI-LIMIT INSTRUCTIONS

FOR TIMER OR PHASE 5 WITHOUT HEAT FAULT

(GAS MODELS ONLY)

This dryer was manufactured with a burner and basket (tumbler)/lint chamber burner manual reset hi-limit

thermostat. If either burner manual reset hi-limit thermostat is open prior to the start of the drying cycle, or during
the cycle, the dryer will not recognize the open state of the burner hi-limit thermostat and will start or continue
through the drying cycle with no heat. The applicable manual reset hi-limit thermostat must be reset manually.

This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper burner

oven operation.

The location of the burner manual reset hi-limit switch is on the right side of the burner box.

IMPORTANT

This dryer is equipped with a burner hi-

limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.

WARNING: Discontinue power to dryer
before attempting to reset hi-limit.

ADC P/N:114093