1. Connect 110VAC /60Hz or 220VAC/ 50Hz to

Heatless Dryer.

2. Connect compressed air line with minimum

of 60 psig and maximum of 100 psig to ¼”
Compressed Air Inlet port (Refer to Figure 1).
Coalescing oil/water pre-filter is recom-
mended for installations where oil or water
mist is present.

3. Purge Air Exhaust ports should be left open

to atmosphere to provide venting (can pipe to
remote location if desired). An inexpensive
particulate after-filter may be used on purge
air exhaust to reduce noise.

4. A 1/4” tubing should be used for connection

to 1/4” Dry Air Outlet fitting. If length of tubing
exceeds 15 meters, 3/8” tubing should be
used.

3-Way Solenoid Valve

Compressed
Air Inlet

Purge Air

Exhaust

Desiccant

Chambers

Dry Air Outlet

HD-Series Heatless Dryers will operate
indefinitely once electrical power and air
pressure are supplied. The number one cause
of failure to dry is compressor oil contamination
of the drying media.

Figure 1

Model Numbers
HD-2000-06-110 (7 “ Dryer, 110 VAC)
HD-2000-06-220 (7” Dryer, 220 VAC)
HD-2000-12-110 (12” Dryer, 110 VAC)
HD-2000-12-220 (12”Dryer, 220 VAC)

Air Requirements
Oil-Free, Non-Condensing Compressed Air

Inlet Pressure
60-100 psig

Inlet Temperature
43 degree C Maximum

Inlet Flow Rate
0-60 LPM (HD-2000-06)
0-90 LPM (HD-2000-12)

Purge Usage
Approximately 10% of Inlet Flow

Outlet Dewpoint
-40 (7” Dryer)
-50 (12” Dryer)

Weight
8 lbs (HD-2000-06)
12 lbs (HD-2000-12)

Depth
5.625” (Both models)

Inlet/Outlet Connections
1/4” Compression Fittings

INSTALLATION

HEATLESS DRYER SPECIFICATIONS

PERFORMANCE