Conduit in w all, Flush box – DoorKing 1812 Classic User Manual
Page 12
1812-065-U-12-13
10
Mount rough-in box into the pilaster, wall or kiosk. Run conduit inside wall into bottom of rough-in box if desired.
Use appropriate hardware (Not supplied) to secure the rough-in box in place.
Remove the 18-pin main terminal connector from the control
board by gently pulling it straight up. This will make wiring to the
control board easier. Note the orientation and numbering sequence of the
connector to correctly wire it.
Re-install control board by carefully routing all incoming wires around it
and secure it in place with 4 screws. Re-connect the keypad plug (cable
points down) and door accessories plug (red wire goes to the left) to the
control board (See 5.2 on page 36 for 1812 wiring information).
Connect all wires to the 18-pin connector (See page 19).
Gently re-connect it back on the control board. DO NOT
APPLY POWER to the 1812 at this time.
Bolt flush box into the
rough-in box with 4
supplied bolts.
Flush Mount in a Pilaster, Wall or Kiosk
Re-install the Control Board
Rough-In Box
CAUTION The control board contains static sensitive compo-
nents. Discharge any static electricity from your hands by
touching a proper ground device before re-installing the
control board. Also make sure that all dirt, metal or wood
debris is removed from inside before re-installing the board.
IMPORTANT
Choose how your 1812
will function (Telephone Mode or
Intercom Mode) on pages 14 thru 18
and run the indicated wires to the
rough-in box. Run ALL wires that
will be needed during the mounting
installation.