Dual Mode Operation

The MotorVac Cool Smoke leak tester utilizes two separate modes for testing:


LEAK TEST MODE: Allows you to quickly determine if a leak exists without smoke.

SMOKE MODE: Quickly finds the leak utilizing both visual-vapour (smoke) and UV dye deposits.

The Cool Smoke fluid is a unique solution that allows for highly visible vapour (smoke) to carry UV dye to leak
points. The UV dye will be deposited at small leak locations where the smoke is forced out a leak.
Your MotorVac Cool Smoke automatically sets the critical pressure that must be maintained during EVAP
testing. You don’t need to set flow rates and you don’t need to be concerned with ambient temperatures or
barometric pressures. The MotorVac Cool Smoke is refillable by the end-user when the smoke-producing
solution is depleted. The smoke it produces, as well as the UV dye, is non-toxic and noncorrosive.
The MotorVac Cool Smoke needs no assembly; it is self-calibrating and requires no maintenance.

Height

12.25 in (31 cm)

Current Usage

0.75 A

Width

13.75 in (35 cm)

Inlet pressure required

80-150 psi (5.5-10.3 bar)

Depth

11 in (28 cm)

Output pressure

13 in H20 (0.03 bar)

Weight

15 lbs (6.8 kg)

Output volume

0.14 SCFM (3.9 L/min)

Ship Weight

18.5 lbs (8.4 kg)

Smoke outlet line

10 ft (3 m)

Power Supply

12 VDC

Power Cord

10 ft (3 m)

Technical Specifications