Inline exchange (cont’d) – MotorVac TRANSTECH IV User Manual
Page 11
[email protected] www.motorvac.com
Inline Exchange (Cont’d)
Automatic Fluid Exchange Operation.
1. Make sure the TransTech IV new fluid tank is filled with the correct type and amount of Transmission
Fluid.
2. Connect TransTech IV power leads to the vehicle’s battery.
3. With vehicle running, pressure should be present at the TransTech IV pressure gauge and the
START ENGINE light should be on solid. If pressure drops to zero, and START ENGINE light is flashing,
the hoses may be reversed.
4. Press START/RESUME button to begin the exchange.
5. When fluid exchange is finished, the COMPLETE light will come on and TransTech will beep continu-
ously until STOP button is pressed.
6. Once transmission service is complete, check ATF level with engine running or as per manufacturer’s
recommendation. Press and hold DRAIN or FILL to adjust ATF level. Stop the engine, the service is
complete.
7. Direct waste hose to a suitable container; open the ball valve on the end of the waste hose and press
EMPTY WASTE button to empty dirty fluid tank.
8
Control Panel
Pressure Gauge