6. Position the retaining clip as shown in Figure 6 and press the sides of the
clip towards the center while inserting the short ends into the holes in the
bracket.
Figure 6. Installing the Retaining Clip
Note
If this is the initial installation of the chassis, refer to the chassis’
Installation Guide for instructions on how to install the remaining modules
in the unit. Otherwise, continue with this procedure to apply power to the
power supply module.
7. Verify that the power switch on the module is set to OFF.
8. Plug the appropriate power cord for your region or country into the AC
power connector on the back panel of the unit and plug the other end into
an appropriate power source. Refer to "Technical Specifications" for the
power requirements of the power supply.
Figure 7. Connecting the AC Power Cord
1114-a
AT-MCF2KPNL3
NORMAL
FAULT
STATU
S
PSU
FAN
M
A
1116-a
AT-MCF2KP
NL3
NORMAL
FAULT
STATUS
PSU
FAN
M
A
9. Lower the power cord retaining clip to secure the power cord to the
chassis. Refer to Figure 8. This is to prevent the power cord from being
inadvertently disconnected from the unit.
Figure 8. Positioning the Power Cord Retaining Clip
10. Power on the AT-MCF2000AC module and the media converter chassis
by setting the power switch to ON.
AT-MCF2000AC Power Supply Module LED
The power supply module has two LEDs. The states of the LEDs are defined
in this table.
Troubleshooting the AT-MCF2000AC Power Supply Module
If you encounter a problem with the power supply module, try the following:
❑ View the LEDs on the module to determine whether the module is operating
normally.
❑ Verify that the module is fully seated in the power supply/fan slot on the
back panel of the chassis.
❑ Verify that the power cord is firmly connected to the power supply module
and the power source.
❑ Verify that the power source is operating properly by plugging a different
device into it.
❑ Replace the power supply module with another power supply module.
LED
State
Description
PSU
Off
The power supply in the module is not receiving
power.
Green
The power supply is operating normally.
Amber
The power supply is experiencing a problem
where the input or output voltage has fallen below
or exceeded the normal operating range.
FAN
Green
The fans in the power supply module are
operating normally.
Amber
A fan has failed and stopped.
1117-a
AT-MCF2KPNL3
NORM
AL
FAULT
STATU
S
PSU
FAN
M
A
❑ Verify that the power from the power source is within the operating
specifications of the power supply module. For the operating specifications
of the power supply module, refer to "Technical Specifications."
Note
For additional assistance, contact Allied Telesis Technical Support on our
web site at www.alliedtelesis.com.
Technical Specifications
Dimensions (H x W x D)
4.1 x 13.3 x 20.6 cm
(1.6 x 5.25 x 8.1 in.)
Weight
1.26 kg (2.75 lb.)
Input Voltage
100-240 VAC 50/60 Hz
Output Voltage
12 volts and 3.3 volts
Operating Temperature:
0° C to 40° C
(32° F to 104° F)
Storage Temperature:
-20° C to 70° C
(-° 4F to 158° F)
Operating Humidity:
Less than 80%
noncondensing
Storage Humidity:
Less than 95%
noncondensing
Maximum Operating Altitude:
3,048 m (10,000 ft)
Maximum Nonoperating Altitude:
4,000 m (13,000 ft)
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
RFI Emissions
FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK,
CE
WARNING:
In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
EMC (Immunity)
EN55024
Electrical Safety
EN60950-1 (TUV), UL 60950-1 (
C
UL
US
)
Copyright
© 2006 Allied Telesis, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with this instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right
to operate this equipment.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.