6. Position the retaining clip as shown in Figure 6 and press the sides of the

clip towards the center while inserting the short ends into the holes in the
bracket.

Figure 6. Installing the Retaining Clip

Note

If this is the initial installation of the chassis, refer to the chassis’
Installation Guide for instructions on how to install the remaining modules
in the unit. Otherwise, continue with this procedure to apply power to the
power supply module.

7. Verify that the power switch on the module is set to OFF.

8. Plug the appropriate power cord for your region or country into the AC

power connector on the back panel of the unit and plug the other end into
an appropriate power source. Refer to "Technical Specifications" for the
power requirements of the power supply.

Figure 7. Connecting the AC Power Cord

1114-a

AT-MCF2KPNL3

NORMAL
FAULT

STATU

S

PSU

FAN

M

A

1116-a

AT-MCF2KP

NL3

NORMAL
FAULT

STATUS

PSU

FAN

M

A

9. Lower the power cord retaining clip to secure the power cord to the

chassis. Refer to Figure 8. This is to prevent the power cord from being
inadvertently disconnected from the unit.

Figure 8. Positioning the Power Cord Retaining Clip

10. Power on the AT-MCF2000AC module and the media converter chassis

by setting the power switch to ON.

AT-MCF2000AC Power Supply Module LED

The power supply module has two LEDs. The states of the LEDs are defined
in this table.

Troubleshooting the AT-MCF2000AC Power Supply Module

If you encounter a problem with the power supply module, try the following:

❑ View the LEDs on the module to determine whether the module is operating

normally.

❑ Verify that the module is fully seated in the power supply/fan slot on the

back panel of the chassis.

❑ Verify that the power cord is firmly connected to the power supply module

and the power source.

❑ Verify that the power source is operating properly by plugging a different

device into it.

❑ Replace the power supply module with another power supply module.

LED

State

Description

PSU

Off

The power supply in the module is not receiving
power.

Green

The power supply is operating normally.

Amber

The power supply is experiencing a problem
where the input or output voltage has fallen below
or exceeded the normal operating range.

FAN

Green

The fans in the power supply module are
operating normally.

Amber

A fan has failed and stopped.

1117-a

AT-MCF2KPNL3

NORM

AL

FAULT

STATU

S

PSU

FAN

M

A

❑ Verify that the power from the power source is within the operating

specifications of the power supply module. For the operating specifications
of the power supply module, refer to "Technical Specifications."

Note

For additional assistance, contact Allied Telesis Technical Support on our
web site at www.alliedtelesis.com.

Technical Specifications

Dimensions (H x W x D)

4.1 x 13.3 x 20.6 cm

(1.6 x 5.25 x 8.1 in.)

Weight

1.26 kg (2.75 lb.)

Input Voltage

100-240 VAC 50/60 Hz

Output Voltage

12 volts and 3.3 volts

Operating Temperature:

0° C to 40° C

(32° F to 104° F)

Storage Temperature:

-20° C to 70° C

(-° 4F to 158° F)

Operating Humidity:

Less than 80%

noncondensing

Storage Humidity:

Less than 95%

noncondensing

Maximum Operating Altitude:

3,048 m (10,000 ft)

Maximum Nonoperating Altitude:

4,000 m (13,000 ft)

Electrical Safety and Emission Statement

Standards: This product meets the following standards when installed in compliant host equipment.

RFI Emissions

FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK,

CE

WARNING:

In a domestic environment this product may cause radio interference in which

case the user may be required to take adequate measures.

EMC (Immunity)

EN55024

Electrical Safety

EN60950-1 (TUV), UL 60950-1 (

C

UL

US

)

Copyright

© 2006 Allied Telesis, Inc. All rights reserved.

No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.

U.S. Federal Communications Commission

Radiated Energy

Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant

to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful

interference when the equipment is operated in a commercial environment. This equipment generates, uses,

and can radiate radio frequency energy and, if not installed and used in accordance with this instruction

manual, may cause harmful interference to radio communications. Operation of this equipment in a residential

area is likely to cause harmful interference in which case the user will be required to correct the interference at

his own expense.

Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right

to operate this equipment.

Industry Canada

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.

4

5

6