MaxPower Corp Eternalite1 User Manual
Page 2

Represented by:
Email: [email protected]
1921 S. Quaker Ridge Place
Ontario, CA 91761
Ph: 1.877.DSPM POWER
1.877.377.6769
Fax: (909)930-3335
*Standard Power Levels...........4.7, 5.25, 7.0, 8.0, 10.0, 12.0, 14.0, 18.0 and 21.0 KW
*Input Voltage ..........................120, 208, 240, 277 or 480 VAC
*Input Voltage Range...............+10%. -15%
*Output Voltage........................120, 208, 277, 480, 120/240 or 120/277 VAC
*Output Voltage Regulation......±2% for all loads and battery discharge mode
*Output Frequency Range........60 Hz, ±1%
Output Wave Form...................Sine-wave <5% @ 100% linear load
Crest Factor..............................2.5:1 typical
Input Protection........................Input Main Circuit Breaker
Output Protection.....................Output Main Circuit Breaker
Surge Protection......................The unit will protect itself and the load
against surges as defined in
ANSI/EEE C62.45 category A and B
Battery......................................Sealed maintenance-free (AGM) lead calcium
Recharge Current.....................Conforms to UL924 standards
External Battery........................Provision for hardware connection of
external battery cabinets or DC source
Efficiency..................................≥92% at 100% linear load
Audible Noise...........................<45dB measured on Response Curve “A”
Safety Agencies.......................Listed to UL standard 924
Operating Temperature............0º to 40ºC (32º to 104ºF)
Storage Temperature...............-20º to 60ºC (-4º to 140ºF)
Humidity...................................5 - 95%, Non-condensing
*Consult factory for others.
Specifications subject to change without notice.
Options:
ECM - Environmental Control Module
NOF120 - Normally OFF Circuit 120VAC
NOF227 - Normally OFF Circuit 277VAC
NOH120 - Normally OFF “Hold On” 120VAC
NOH227 - Normally OFF “Hold On” 277VAC
OCB - Output Circuit Breaker(s)
EPO- Emergency Power Off
RSSP - Remote Indicator Panel
SNMP - SNMP Card
FAX - Fax Modem
FC - Form C Contacts
SRB - Seismic-Rated Bracket
STU1 - Onsite Startup
IDB - Internal Dimmer Bypass
EMB - External Maintenance Bypass
EW - Extended Warranty
UPS
Battery
Weight
Power
Rating
Eternalight
1
Series
OE1
(Consult
factory
for others)
Cabinet
Dimensions
Cabinet
Dimensions
(com-
bined)
KVA/KW
W
H
D
W
H
D
(lbs)
4.7
42”
71”
22.5”
not required
5.25
42”
71”
22.5”
not required
7.0
42”
71”
22.5”
not required
not required
not required
not required
not required
8.0
42”
71”
22.5”
10.0
42”
71”
22.5”
12.0
42”
71”
22.5”
14.0
42”
71”
22.5”
18.0
42”
71”
22.5”
1200
1200
1450
1450
1820
2210
2550
21.0
42”
71”
22.5”
4375
3750
42”
71”
22.5”
42”
71”
22.5”