MAINTENANCE AND REPAIR
TROUBLESHOOTING
VERIFY THAT ALL POWER IS REMOVED BEFORE HANDLING THE UNIT.
Verify that the unit channel addresses are correctly set.
Check that the console is powered and that console channels are correctly patched or set.
Check the control cable between the dimmer and its console.
Verify the loads and their connections.
OWNER MAINTENANCE
There is one fuse in the unit which provides protection for the unit's printed circuit board . It may be replaced only
with a 1/2 Amp, 250VAC, Fast acting replacement fuse.
There are no other user serviceable parts inside the unit.
The best way to prolong the life of your unit is to keep it cool, clean, and dry. It is important that the cooling intake
and exit vent holes are clean and unobstructed.
Service by other than Lightronics authorized agents may void your warranty.
OPERATING AND MAINTENANCE ASSISTANCE
If service is required, contact the dealer from whom you purchased the equipment or return it to the Lightronics
Service Department, 509 Central Drive, Virginia Beach, VA 23454. TEL 757 486 3588. All items returned for
service must include a description of the problem along with your name, address, and phone number.
Lightronics recommends that you record the serial number of your DB-612 for future reference.