RE - 82 RACK MOUNT DIMMER

Revision 2.4

OWNERS MANUAL

11/29/2007

www.lightronics.com

Lightronics Inc

509 Central Drive, Virginia Beach, VA 23454

TEL 757 486 3588



MAINTENANCE AND REPAIR

CIRCUIT BREAKERS AND FUSES

Each channel of the RE-82 is protected by a 20 Amp, fast acting, magnetic circuit breaker located on the front
panel of the unit. If the total load for a channel is greater than 2400 Watts the channel circuit breaker will trip.

There are two 1/2 Amp., 250 Volt, fast acting fuses on the front panel to protect the internal electronic circuits
from an overvoltage condition. These fuses may be replaced ONLY by fuses of the size and type given above.

TROUBLESHOOTING

VERIFY THAT ALL POWER IS REMOVED FROM THE DIMMER BEFORE HANDLING THE UNIT.

Verify that the unit channel addresses are correctly set.

Check that the console is powered and that console channels are correctly patched or set.

Check the control cable between the dimmer and its console.

Verify the loads and their connections.


OWNER MAINTENANCE

There are no user serviceable parts inside the unit.

The best way to prolong the life of your unit is to keep it cool, clean, and dry. It is important that the cooling intake
and exit vent holes are clean and unobstructed.

Service by other than Lightronics authorized agents may void your warranty.

OPERATING AND MAINTENANCE ASSISTANCE

If service is required, contact the dealer from whom you purchased the equipment or contact Lightronics, Service
Department, 509 Central Drive, Virginia Beach, VA 23454 TEL 757 486 3588 All items returned for service
must include a description of the problem along with your name address and phone number.

Lightronics recommends that you record the serial number of your unit for future reference.

SERIAL NUMBER ______________________