5
Maintenance
Torque Chart
Reassembling the Strainer
( See Page 7 For Item Numbers)
1. Place the strainer basket into the housing.
2. Place the end cover O-Ring (4) in the groove in the
end cover (2).
3. Place the end cover (2) with the O-Ring installed, on
the strainer housing end (1).
4. Fasten the end cover with the 4 washers (8) and
screws (7). Evenly tighten all screws.
Tightening Screws and Nuts
Leakage that occurs after tightening the fasteners
indicates a damaged seal or distortion to the surface of
the cover. In either of these cases, the seals or cover
must be replaced. Excessive tightening will not stop the
leakage. See chart below for proper torque standards.
*Torque specifications are ±10%.
Bolt Size
Foot-Pounds
Newton-Meter
Foot-Pounds Newton-Meter
NOMINAL*
NOMINAL*
NOMINAL*
NOMINAL*
#8 (.164) - 32 UNC-2A
3.5
4.8
#10 (.190) - 24 UNC-2A
5.2
7.1
1/4" (.250) - 20 UNC-2A
7.3
9.9
5/16" (.3125) - 18 UNC-2A
15.3
20.7
3/8" (.375) - 16 UNC-2A
27
37
7/16" (.4375) - 14 UNC-2A
43
58
1/2" (.500) - 13 UNC-2A
66
90
112
152
5/8" (.625) - 11 UNC-2A
132
179
222
301
3/4" (.750) - 10 UNC-2A
233
316
395
535
Grade 8
Grade 5 Fasteners