CONTREX CX-1010 User Manual
Page 6
Page 6
Motor Drive Set Up
In order to achieve desired system performance, the motor drive connected to the
CX-1010's speed command output must be properly set up. Refer to your motor
drive manual to assist you in making the following four motor drive adjustments:
• Set the maximum speed adjustment on the drive to deliver 10% more
speed than the expected maximum speed required for your application.
• Set the acceleration and deceleration times to their fastest settings.
• Set the IR compensation to its minimum setting.
• Set the zero speed (balance) adjustment for zero creep.
Operator Interface Primer
The remainder of the CX-1010 set up procedures involve setting control parameter
values through the operator interface, and then verifying system behavior using
monitor parameters. The basic procedure for changing a control parameter is first to
locate the relevant parameter using the Menu, Page Up/Down and Parameter
Up/Down keys, and then to modify the parameter value using the Numeric or Scroll
Up/Down keys.
The sequence for locating a control or monitor parameter using the menu driven
interface is:
• Press the Menu key repeatedly until the Main Menu is displayed.
• Press the Parameter Up/Down keys to select the sub menu.
• Press the Enter key.
• Press the Parameter Up/Down keys to select the parameter category.
• Press the Enter key.
• Press the Page Up/Down keys, if necessary, to select the page.
• Press the Parameter Up/Down keys to select the parameter.
An alternative method for locating a parameter is through the code select procedure:
• Press the Status key to display the Status screen.
• Press the Code key to activate the code select line.
• Enter the numeric parameter code.
• Press the Enter key.
• The selected parameter is now displayed on the Status screen.
For each control parameter (CP) and monitor parameter (MP) required, the menu
path will be shown as:
Go to MAIN MENU\SETPOINTS\RUN MODES\.
Enter Setpoint Mode {CP 102} = Drct.
The menu selections are separated by back slashes, "\". The parameter code is
shown in the brackets,{}.