Specifications – KP Electronic Systems EXR5000 User Manual
Page 2
www
.kpsystems.com
Head Office:
P.
O. Box 42,
Tefen Industrial zone, 24959, Israel.
Tel: 972-4-9873066, Fax: 972-4-9873692,
US Office:
109
Tudor Drive, North W
ales, P
A 19454 USA.
Tel: (888) 542-7460, Fax: (215) 542-7461,
Specifications
485 mm , (19)
302 mm
(12)
133 mm
(5.25)
RF Transmitter
Models
EXR5000
TM
(VHF)
General
Power Supply Input Voltage
Frequncy
Modulation
Power Output
Frequency Setting
Frequency Stability
85-265 VAC, 45-65 Hz
136-174 MHz
FM, FSK, DFM
10 or 25 Watt
Synthesized
Sensitivity
Selectivity
RF Receiver
0.3
m
V (-116 DBM) for 12dB SINAD
AC Mains, Current Consumption
Backup Battery
0.4A on 220VAC supply, 0.8A on 110VAC supply
12 VDC, 7 Ah Lead Acid
Spurious & Harmonics
Deviation
-65dB
5KHz max for DFM 12.5KHz bands, 3.3KHz for 25KHz
bands on FSK
Operating DC Voltage
10.5 - 14.5 VDC
Standby Current Consumption
120mA
Transmission Current
Output Impedance
3/8 A max, depends on output power
50W
UHF Connector
FCC (USA) - Using:
BSR100
TM
,
BSRU100
TM
Standarts
FCC ID: H78KPBSR100; Emmission Designator: 11K0F2D
ETSI (CE) - Using:
Motorola
TM
-
GM340
TM
ETSI 300 113
EXR5000
TM
(UHF)
403-504 MHz
2.5 ppm
+-
65dB at 12.5 KHz
+-
Signal Strength Meter
0.5uV - 2uV analog meter, digital conversion (optional)
Backup Time
Min. 24 hours with fully charged internal battery,
operating in a transmit/receive ratio of 1:20
Operating Temperature
-30
o
C to +60
o
C (-22
o
F to +140
o
F)
Storage Temperature
-40
o
C to +70
o
C (-40
o
F to +158
o
F)
7 kg (15.4lbs) (without battery)
VHF
UHF
Size
Physical Dimensions
19, 2U, 485 x 133 x 302 mm
Weight
BROCH.033
Rev
. New
(not supplied)
Backup Battery Operating Time