Routine maintenance – Hydrotech 104 Series ADVANCED MULTI STAGE WATER TREATMENT SYSTEM User Manual
Page 15

- 11 -
ROUTINE MAINTENANCE
RECOMMENDATIONS
HAVE ALL COMPONENTS ON HAND AND READY BEFORE BEGINNING PROCEDURE.
A CLEAN WORK AREA AND EQUIPMENT ARE ESSENTIAL TO PROPERLY CLEAN AND/OR SANITIZE THE SYSTEM.
(I.e., CLEAN HANDS, TOOLS, WORK SURFACE, AND CONTAINERS)
SERVICE REQUIREMENTS
To insure the system operates at its optimum level,
certain routine maintenance must be performed.
Frequency of maintenance performance will depend on
feed water quality and level of system usage.
CLEAN: Each time filters are replaced
SANITIZE: At least once every 12 months.
EQUIPMENT NEEDED
Safety glasses
Rubber gloves, sanitary
Wash Cloth, Clean and Lint-free
Household bleach - Unscented Only
(5 1/4% sodium hypochlorite)
Liquid dish soap
Plastic bucket, Plastic bowl
“O” Ring Lube FDA Approved
(P/N 30300026)
REPLACEMENT FILTER SETS
“O” RINGS
P/N 41400011 Carbon Filter, VOC Reduction (White Cap) - 1 each
P/N 41400010 Carbon Filter, Lead Reduction (Black Cap) - 3 each
P/N 34201010 Filter Cartridge
P/N 34201026 Filter Housing
CLEANING, SANITIZING, AND CARTRIDGE REPLACEMENT PROCEDURE
1. Mix a mild cleaning solution of dish soap and clean
potable water in the plastic bowl.
2. Shut feed water supply valve and open product water
faucet to relieve system pressure.
3. CAUTION: Do not attempt to remove filter housings
until water flow stops. This reduces pressure inside
the system so housings may be removed safely.
CAUTION: Additional point-of-use devices (i.e.,
icemakers) may use filters along their supply line.
Remove any filter or treatment device installed
between module and delivery device before
proceeding.
Remove each filter housing by turning it counter-
clockwise. Remove each filter cartridge as its housing
is removed. Discard filters.
Icemaker: Transfer ice cubes from bin/tray to clean
freezer container for storage until procedure is done.
4. CAUTION: Use sanitary rubber gloves for this
procedure to avoid contaminating sanitizing solution or
filters. Wear gloves whenever cleaning/ sanitizing
system components or handling new filter cartridges.
Remove filter housing "O" rings and wash them with
cleaning solution. Rinse them well with clean potable
water. Inspect the "O" rings for damage (i.e., nicks or
scratches). Replace damaged "O" rings.
5. CAUTION: Do not get the Smartap
®
Flow Monitor
electronics, wiring, or connectors wet.
Clean filter housings and manifold ports, inside and
outside with washcloth and cleaning solution. Do not
use abrasive materials.
6. Rinse housings/manifold with clean potable water.
7. Inspect manifold and filter housing "O" ring groove
area for damage (i.e., nicks or scratches). Replace
damaged
components.
8. Place a small amount of "O" ring lubricant over the
surface of the filter housing "O" ring. Install the "O" ring
into the filter housing groove.
TO SANITIZE SYSTEM: Complete Steps 9-29.
TO INSTALL FILTERS: Complete Steps 17-29.
WARNING: WEAR SAFETY GLASSES WHILE
PERFORMING THIS PROCEDURE.
WARNING: READ THE "WARNINGS" ON THE BLEACH
CONTAINER BEFORE USING.
WARNING: HANDLE SANITIZING SOLUTION
CAREFULLY. AVOID CONTACT WITH UNPROTECTED
AREAS.