Operating Instructions
Setting the Frequency of Automatic Regeneration
Setting the 24 Hour Timer
The 24 hour timer must correspond with the correct time of day to ensure proper cycling of your filter.
•
Disengage the drive gear by pressing and holding in the red button on the left side of the control.
•
Now turn the large dial until the actual time of day is at the time of day arrow at the bottom of the panel.
•
Release the red button and check for firm engagement at setting.
•
The correct time of day on the 24 hour clock has now been set.
Time of Automatic Regeneration
The time of automatic regeneration is factory set at 12:00 a.m.
The amount of iron, manganese and sulfur to be removed per day
must first be determined using the following calculations:
Number of people in the household
x 60 gallons of water per person
= Number of gallons of filtered water required per day
x ppm of iron in the water sample
= TOTAL AMOUNT OF IRON TO BE REMOVED PER DAY.
5600CC Model
2510CC Model
- PH-200 pH_TEMP METER (5 pages)
- SL1252-16-7000 Residential Scaleless System (12 pages)
- SL20BB-5 POU Scaleless (8 pages)
- SL1252-30 Scaleless POE Residential System (12 pages)
- 2510 Valve Chemical Free Iron Filter Operation Manual (12 pages)
- 5600 Valve Automatic Water Filters: Activated Carbon, Turbidity (Multi-Media), Neutralizing (12 pages)
- 5600 SXT Valve Iron & Sulfur Filter Operation Manual (16 pages)
- 5600 SXT Valve Carbon & Multi-Media Filter Operation Manual (12 pages)
- 5600 SXT Valve Chem Free Iron Filter Operation Manual (18 pages)
- 7000 SXT Valve nextSand Turbidity & Sediment Filter Operation Manual (12 pages)
- 5600 SXT Valve nextSand Turbidity & Sediment Filter Operation Manual (12 pages)
- 2510 Valve nextSand Turbidity & Sediment Filter Operation Manual (8 pages)
- 2510 AIO SXT Chemical Free Iron Filter Operation Manual (16 pages)
- 2510 Service Manual (40 pages)
- 2510 Service Manual (36 pages)
- 2510 AIO Supplemental Insert (2 pages)
- AP2 (230V) Air Pump & Retention Tank Kit (8 pages)
- FreshPoint U440 Ultrafiltration System (36 pages)
- 5600 SXT Valve Downflow Automatic Water Softeners Operation Manual (12 pages)
- 6200 SXT Automatic Meter Initiated Water Softener (44 pages)
- 6700 XTR Valve Downflow Automatic Water Softeners Operation Manual (12 pages)
- 6700 XTR Valve Downflow Automatic Water Softeners Service Manual (40 pages)
- 6700 XTR Valve Upflow Automatic Water Softeners Operation Manual (12 pages)
- 6700 XTR Valve Upflow Automatic Water Softeners Service Manual (40 pages)
- 7000 SXT Valve Water Softener Operation Manual (12 pages)
- ProFlo SXT Valve Downflow_Upflow Automatic Water Softeners Operation Manual (16 pages)
- ProFlo SXT Upflow Automatic Water Softeners Service Manual (44 pages)
- 5600 Meter Initiated_Calendar Clock Valve Automatic Water Softeners (12 pages)
- 9100 SXT Valve Meter Initiated Water Softener (12 pages)
- 9100 SXT Valve Meter Initiated Water Softener (16 pages)
- 7000 Master Programming Mode (10 pages)
- 7000 Service Manual (32 pages)
- 7000 SXT Valve Water Softener (14 pages)
- 5600 SXT Valve Water Softener (16 pages)
- 6700 XTR Downflow Valve Water Softener (12 pages)
- 6700 XTR Upflow Valve Water Softener (12 pages)
- 5600 SXT User Programming Chart (10 pages)
- 5600 SXT Downflow Service Manual (48 pages)
- 9000 Commercial TMI Water Softener (52 pages)
- SXT Timer (24 pages)
- 5600 SXT Valve Mini Water Softener (12 pages)
- 5600 Calendar Clock Valve Organic Color Removal & Softener (12 pages)
- 5600 Service Manual (36 pages)
- 5600 Meter Initiated_Calendar Clock Valve Iron Softener (12 pages)