beautypg.com

Technical data, Storage – Amcor PLM 15000E User Manual

Page 11

background image

11

TECHNICAL

DATA

Model

9000E

12000E

15000E

Cooling capacity *

BTU/h

7000

9000

12000

kW

2

2,6

3,5

EE Class*

A

EER*

2,8

Power consumption

W

880

1100

1330

Current

A

4

5

6

Mains

V / Hz / PH

220 - 240 / 50 / 1

Air delivery max.

m3/h

450

Dehumidification max.**

L/24h

20

For rooms up to

m2

75

Compressor model

rotary

Fan speeds

3 (2+1 turbo)

Thermostatic range

°C

18 - 32

Noise level

dB

49

Protection class

IP 21

Refrigerant charge

type / g

R407C / 480

Dimensions (w x h x d)

mm

555 x 800 x 455

Net weight

kg

31,5

34

39

* measured conform EN 14511.

** moisture removal at 32°C, 80% RH.

Subject to modifi cations without prior notice. For greater precision, please refer to the rating label placed on
the product.

Empty the internal water container.
Clean the screen filter.
Remove 3M Filtrete™ filter and active carbon filter.
• Remove the 3M Filtrete™ filter and active carbon filter before end of season storage and

install new filters at the beginning of the new season.

The old filters can be disposed of in the ‘Non-biological rubbish
container’.
• Replacement filter packages are available from Amcor.
Put the unit in Fan Only mode for a few hours to ensure that the inside
becomes completely dry.
Store the cable as shown.

Protect the unit against dust and store in a dry place, not accessible to children.

STORAGE

Reminder:
Waste electrical products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.

This manual is related to the following products: