Troubleshooting – Hydra-Flex Aqua-Lab CS1 Prep Installation and Operating Manual User Manual
Page 10

Operating Manual
© Hydra-Flex Inc 2011
- 8 -
Troubleshooting
PROBLEM
POTENTIAL CAUSES
SOLUTIONS
Pump not primed
See priming instructions
Inlet Restriction
Check all in-line filters and inlet plumbing for restrictions.
Check valves and backflow preventers
Inadequate water supply
Check pressure on inlet side of pump to be sure positive
pressure is maintained
Undersized piping
Replace with larger piping
Leak on the Inlet side
Make sure connections are tight
Worn or defective pump parts
Replace worn parts or entire pump, Clean parts if required
Pump check valves cloged
Clean and check all 6 pump check valves
Incorrect Motor rotation
Reverse motor rotation by interchanging any two leads
Blown fuse or circuit breaker
Replaced fuses or close circuit breaker
Defective Motor Starter
contactor
Replaced motor starter contactor
Defective pressure switch
Replace pressure switch
Incorrect Motor Voltage
Voltage must be within 10% of motor rated voltage
Defective motor
Replace motor
Pump components damaged
Replace worn part or entire pump
Not Primed
Reprime pump
Pump not secured firmly
Secure properly
Restricted Inlet
Clean or correct restriction
Water regulator fluttering
Try to adjust regulator down and then back up or replace
regulator
Pump check valves cloged
Clean and check all 6 pump check valves
Cavitation (Sounds like marbles
in pump)
Increase inlet size
Pressure Switch set too low
Increase set point of pressure switch
Foam generator clogging
clean foam generator
Worn mechanical seal
Replace shaft seal
Worn o-ring seals
Replace
Injector is not
drawing chemical -
Passes Vacuum
Pressure check
test
Clogged chemical feed
Check chemical hose, foot valve, metering tip and hose barb
for debris or clogs
Too much back pressure on
injector
Perform back pressure check test outlined in Section IV if this
manual. If the result is higher than 66 psi then Increase arch
nozzle size or quantity, use larger tubing, or use a smaller flow
injector
Clogged injector check valve
Blow compressed air through the chemical hose barb on the
injector to remove debris
Clogged injector nozzle
Remove injector and blow out any debris with compressed air
Pump won't start or
run at full speed
Pump Operates, but
delivers little or no
water
Injector is not
drawing chemical -
Fails Vacuum
Pressure check
test
Pump Leaks
Excessive Noise from
Pump
Pump cycles on and
off