Hudson Valley Lighting TRAVIS 5912-5924 User Manual
Hudson Valley Lighting Lighting
5912,5916,5920,5924
GENERAL
1. To ensure successful installation, the following instructions and diagram(s) should
be read and understood.
2. All electrical connections must be made in accordance with the National Electric
code and local codes and ordinances. If you are uncertain how to install electrical
wiring and lighting fixtures, secure the services of a qualified licensed electrician.
TOOLS NEEDED
Blade screwdriver, phillips screwdriver, slip joint pliers or small adjustable wrench,
wire cutter/stripper, electrical current tester, stepladder and electrical tape.
INSTALLATION PREPARATION
1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING
FIXTURE IS TO BE ATTACHED. Move the appropriate circuit breaker to the “off
position or completely remove the fuse controlling the circuit.
2. If an existing fixture is being replaced, remove it and note to which of the wires
in the outlet box the fixture was attached. DO NOT SEPARATE ANY OTHER
WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF
OLDER WIRING. In regular circumstances the BLACK wire will be the “Hot” lead
and the WHITE wire will be the “Neutral” or “Common” lead. A GREEN or BARE
COPPER wire is the “Ground”. In older buildings it is always good practice to
reconfirm the polarity of the wiring.
3. This fixture is designed to be mounted on a standard round or octagon box. The
box must be securely mounted to the structure of the building.
FIXTURE INSTALLATION
1. Remove the fixture, shades and parts bag(s) from the carton. Before discarding
the carton, double-check packing to make certain that all parts are found.
2. Attach the mounting bar to the outlet box. (The green screw should face out).
Pull wires out of box. Thread the nipple onto the mounting bar.
3. Thread the fixture loop onto the fixture; twist the center column onto the
nipple on the wire box.
4. Thread wires through ring and canopy and let canopy slide down chain.
5. Open end links of chain and attach the chain to the loop. Close the top link of
chain. Hang the fixture on the chain at the desired height. Remove excess chain.
Close the bottom link of chain.
6. Measure 6" of lead wire beyond the end of the chain. Cut off excess wire.
Strip the insulation off the ends of the leads exposing approx. 1/2 " of wire.
Twist the strands of wire together. Push the leads and ground wire up through
the screwcollar loop and nipple and into the outlet box.
7. Fasten the green fixture wire to the green or bare copper wire in the box or
fasten it to the mounting plate with green screw provided.
NEVER FASTEN THE GROUND WIRE TO THE BLACK OR “HOT” WIRE!
FAILURE TO FOLLOW THIS INSTRUCTION COULD RESULT IN SERIOUS
INJURY OR DEATH!
8. Fasten the white fixture wire to the white wire in the outlet box. Fasten the wires
together with an approved fastener (wire nut). Starting about 1” below the fastener,
tightly wrap connection with electrical tape so that the tape seals the end of the
fastener.
Make sure that there is no exposed wire or strands that could
cause a dangerous short circuit !
9. Connect the black fixture wires to the black wire in the outlet box.
Fasten the joined wires as in step 8.
10. Slide the canopy and screwcollar ring up the chain and secure the canopy to
the ceiling.
Continued next page.