beautypg.com

Equipment clearances, Plumbing schematic, Electrical requirements – Aquacal 35 EN User Manual

Page 3

background image

Page 2

SECTION 2 - INSTALLATION

For commercial or complete installation instructions please, visit www.AquaCal.com for equipment manual.

EQUIPMENT CLEARANCES

Keep the area immediately adjacent to the heat pump clear of items such as shrubs and bushes, lawn furniture,
chemicals containers, etc. These items can prevent air from circulating properly through the heater, and will result in
inefficient operation and/or damage to the heat pump.

Figure 1

Figure 2

PLUMBING SCHEMATIC

3 = Three-Way Valve

B = Bypass Check Valve (5lb) for Water Flow

Over Max Flow (see

Specifications

for details)

C = Chlorinator

D = Main Drain

F = Filter

H = Heat Pump

P = Water Pump

R = Return

S = Skimmer

Figure 3

ELECTRICAL REQUIREMENTS

1)

Locate the equipment power disconnect within 6-

feet of the heater’s electrical enclosure.

2)

Never mount power disconnects directly to heat pump.

3)

Only use copper conductors.

4)

Use sequencing controllers when multiple heaters are installed on site.

5)

Local codes and regulations may require the use of a ground fault interruption device (GFI Circuit Breaker).
Nuisance tripping of these devices is common and not covered under the terms of the Manufacturer’s warranty.

6)

Review online product manual when connecting external controller devices to heat pump.

Overhang with

Gutter

5 feet Minimum Clearance
Overhead

Rain Run-Off Must Be
Directed Away From
Heater

(Front)

30” Minimum

Clearance

(Rear)
12” Clearance for all

IceBreaker / Heat &
Cool Models

12” Clearance for All

Tropical Models

6” Clearance for SQ

“Heat Only” Models

(Rear)

12” Clearance for All IceBreaker / Heat &

Cool Models

12” Clearance for All TropiCal Models

6” Clearance for SQ “Heat Only” Models

(Side)

12”

(Side)

12”

(Front)

30”

F

P

3

S

D

POOL

R

C

B

H

This manual is related to the following products: