beautypg.com

Global Specialties PB-501 - Manual User Manual

Page 9

background image

9

f. Leave wires connected.

6. LATCH TEST

a. Jumper CLOCK X to PB1. Jumper CLOCK Y to

PB2. A l l LEDs should be l i t .

b. Set switch "0" thru 3 to not OPEN. A ll LEDs

should be l i t . Press and release P B 1 ; "D0" thru
“D3” should go out.

c. Set switch 4 thru 7 to not OPEN. “D4”

through “D7” should s t i l l be l i t .
Press and release PB2; “D4” through “D7” should go out.
Remove CLOCK jumpers.

7. INPUT PORT TEST

a. Jumper ENABLE X to PB1.

Jumper ENABLE Y to PB2. A l l
LEDs should be out.

b. Set a ll 8 switches to OPEN. A l l LEDs

should s t i l l be out.

Press and hold PB1: "D0"

through “D3” should l i g h t .

Release PB1: "D0"

through “D3” should go out.

P

ress and hold PB2: “D4” through “D7” should light.

Release PB2: “D4” through “D7” should g o out.

8. Turn POWER switch OFF: Unit should not function.



CHECKOUT COMPLETE