Pump operation, Typical manual dewatering installation, Manual operation – BJM Pumps SV1500F-230 User Manual
Page 8: Typical automatic dewatering installation
8
PUMP OPERATION
This pump is designed to handle dirty water that contains some
solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.
Do not operate this pump where explosive vapors or
flammable material exist. Death or Serious injury may result.
TYPICAL MANUAL DEWATERING INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
MANUAL OPERATION
All SVF models
are provided with a 50’ (15 m) power cable. NEVER splice the power
cable due to safety and warranty considerations. Always keep the plug end dry.
Do not alter the length or repair any power cable with a splice. The
pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.
The BJM Pumps, SV-F series pumps require a special control that contains the starting
components, thermal sensor and Seal Minder connections. These pumps cannot be
directly connected to a power source.
TYPICAL AUTOMATIC DEWATERING INSTALLATION