beautypg.com

Pump runs but does not deliver rated capacity, Servicing your submersible pump, Maintaining your pump – BJM Pumps SX1500CSS-F User Manual

Page 13: Changing seal oil

background image

13

PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY

1. Discharge line clogged, restricted or hose kinked. Check discharge hose/pipe.
2. Worn impeller and/or suction cover. Inspect and replace as necessary.
3. Pump overloaded due to liquid pumped being too thick.
4. Pumping air. Check liquid level and position of pump.
5. Excessive voltage drops due to long cables.
6. Pump running backwards, check rotation.

SERVICING YOUR SUBMERSIBLE PUMP

Pump should be disconnected from the electric power supply before proceeding to do
any service or maintenance.

The design of the “F” series high temperature pump models is unique and
requires specific knowledge to perform the proper assembly. BJM Pumps
recommends that all electrical service work be performed at the factory, or by a
factory trained and certified repair technician, to insure that the materials and
assembly methods meet BJM standards.

MAINTAINING YOUR PUMP

Pump should be disconnected from the electric power supply before proceeding

to do any service or maintenance.

Pump should be inspected at regular intervals (At least 2 times per year).

More frequent inspections are required if the pump is used in a harsh

environment.

Preventative maintenance should be performed to reduce the chance of

premature failure.

Worn impellers and lip seals should be replaced.

Cut or cracked power cables must be replaced. (Never operate a pump with a

cut, cracked or damaged power cable.)

Seal oil should be checked once per year.

Maintenance should always be done when taking a pump out of service before

storage.

1) Clean pump of dirt and other build up.
2) Check condition of oil around the shaft seals.
3) Check hydraulic parts: check for wear.
4) Inspect power cable. Make sure that it is free of nicks or cuts.

CHANGING SEAL OIL

Changing the seal oil in the S-F & SX-F Series pumps is very easy.

1) Make sure that the pump is de-energized and locked out for service.
2) Lay the pump down on its side.