beautypg.com

Trouble shooting, Pump will not run, Pump runs but does not deliver rated capacity – BJM Pumps KB110H-F User Manual

Page 13

background image

12

Before installing a pump, check the pump rotation to insure that wiring has been
connected properly to power source, and that the green lead of power cord (See wiring
diagram), is connected to a valid ground, momentarily energize the pump, observing the
directions of kick back due to starting torque. Rotation is correct if kick back is in the
opposite direction of rotation arrow on the pump casing. If rotation is not correct,
switching of any two power leads other than ground will provide the proper rotation.

BJM three phase pumps do not have integral motor overload protection. BJM
recommends that all three phase pumps using a motor starting device also incorporate
motor overload protection. Pumps must be installed in accordance with the National
Electrical Code and all applicable local codes and ordinances. Pumps are not to be
installed in locations classified as hazardous in accordance with National Electrical
Code, ANSI/NFPA 70.

Connect pump to a junction box, outlet box, control box, enclosure with a wiring
compartment that meets NEC and local codes. The provision for supply connection
shall reduce the risk of water entry during temporary, limited submersion and shall
comply with the applicable requirements of the Standard for Enclosures for Electrical
Equipment, UL 50, or the standard for Metallic Outlet Boxes, UL 514A, and the standard
for Motor-Operated Water Pumps. UL 778.

TROUBLE SHOOTING

Disconnect the power source to the pump BEFORE attempting
any type of trouble shooting, service or repair.

PUMP WILL NOT RUN

1. Check power supply (fuses, breaker). Reset power.
2. Blocked impeller. Remove strainer, check and clean.
3. Defective cable or incorrect wiring.
4. Strainer clogged. Check and clean as necessary.
5. Float switch tangled/obstructed. Clean and free float switch from obstruction.
6. Float switch defective. Replace float switch.
7. Pump overheated or temperature of liquid exceeds pump operating

temperature.

PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY

1. Discharge line clogged, restricted or hose kinked. Check discharge hose/pipe.
2. Worn impeller and/or suction cover. Inspect and replace as necessary.
3. Pump overloaded due to liquid pumped being too thick.
4. Pumping air. Check liquid level and position of pump.
5. Excessive voltage drops due to long cables.
6. Three phase only; pump running backwards, check rotation.

This manual is related to the following products: