INSPECTION
Review all safety information before servicing pump.
The following are recommended installation practices/procedures for the pump. If there
are questions in regards to your specific application, contact your local BJM Pumps
distributor or BJM Pumps, LLC.
PRE-INSTALLATION INSPECTION
1) Check the pump for damage that may have occurred during shipment.
2) Inspect the pump for any cracks, dents, damaged threads, etc.
3) Check power cord for any cuts or damage.
4) Check for, and tighten any hardware that appears loose.
5) Carefully read all tags, decals and markings on the pump.
If anything appears to be abnormal, contact your BJM Pumps distributor or BJM
Pumps, LLC. If damaged, the pump may need to be repaired before use. Do not install
or use the pump until appropriate action has been taken.
Lubrication:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated
from the factory. Seal oil should be checked once per year. See table below.
OIL FILL QUANTITY/TYPE
Pump Models
Qty. oil in seal chamber
Type of oil
(U.S. fl. oz.) Metric C.C.
LWA1500
21
620
ISO 32 NSF Food Grade Mineral Oil
LWA15
21
620
ISO 32 NSF Food Grade Mineral Oil
LWA2200
21
620
ISO 32 NSF Food Grade Mineral Oil
LWA22
21
620
ISO 32 NSF Food Grade Mineral Oil
LWA37
21
620
ISO 32 NSF Food Grade Mineral Oil
LWA55, LWA55H
28.8
850
ISO 32 NSF Food Grade Mineral Oil