Inspection, Pre-installation inspection, Oil fill quantity/type – BJM Pumps RX15SS-575T User Manual
Page 6
6
INSPECTION
Review all safety information before servicing pump.
The following are recommended installation practices/procedures for the pump. If there
are questions in regards to your specific application, contact your local BJM Pumps
distributor or BJM Pumps, LLC.
PRE-INSTALLATION INSPECTION
1) Check the pump for damage that may have occurred during shipment.
2) Inspect the pump for any cracks, dents, damaged threads, etc.
3) Check power cord for any cuts or damage.
4) Check for, and tighten any hardware that appears loose.
5) Carefully read all tags, decals and markings on the pump.
If anything appears to be abnormal, contact your BJM Pumps distributor or BJM
Pumps, LLC. If damaged, the pump may need to be repaired before use. Do not install
or use the pump until appropriate action has been taken.
Lubrication:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated
from the factory. Seal oil should be checked once per year. See table below.
OIL FILL QUANTITY/TYPE
Pump Models
Qty. oil in seal chamber
Type of oil
(U.S. fl. oz.) Metric C.C.
R100
9.5
280
ISO 32 NSF Food Grade Oil
R250, R400, R400D, R400P
1.35
40
ISO 32 NSF Food Grade Oil
R750, R1500, R1530, R1520
3.7
110
ISO 32 NSF Food Grade Oil
RX750SS, RX1500SS
4.4
130
ISO 32 NSF Food Grade Oil
R400L, R400L-3
4.4
130
ISO 32 NSF Food Grade Oil
R08, R15
3.7
110
ISO 32 NSF Food Grade Oil
RX08SS, RX15SS
4.4
130
ISO 32 NSF Food Grade Oil