Vi-6 rear panel controls – Biamp VI-6 User Manual
Page 6
![background image](/manuals/329641/6/background.png)
6
VI-6 REAR PANEL CONTROLS
Network Connection
The VI-6 has one RJ45 connector located on the rear panel that utilizes standard Ethernet cabling to interface the VI-6 to the Vocia system
via a managed network switch. The RJ45 connector provides two LEDs that indicate Ethernet link and network activity (see table below).
Device ID
The rotary ID switches are located on the back of the VI-6 and give the unit a unique Device ID. The switches are in hexadecimal
format. All VI-6 units must have a unique Device ID to function properly within a Vocia Paging World (i.e., it is not possible to have
two VI-6 units with the same Device ID of hex 07). To assign a Device ID of hex 07, turn the LSB switch to 7 and leave the MSB
switch on 0. To create an ID of hex B7, turn the LSB switch to 7 and turn the MSB switch to B. Device ID switches should be set using
a 0.1 inch (2.5mm) to 0.12 inch (3.0mm) flat blade screwdriver. More information on setting IDs and the hexadecimal numbering
scheme used in Vocia can be found in the Vocia Help File.
Please note: Changes made to the Device ID while connected to the network require a power cycle in order to take effect.
CobraNet
The VI-6 is a CobraNet device. All CobraNet routing and bundle assignments are processed by the Vocia devices locally.
Vocia devices are not interoperable with non-Vocia devices.
C NC NO C NC NO C NC NO C NC NO
Paging Ports
1 2 3 4
1 2 3 4
Control Outputs
3 4 10V
(100mA)
L R
L R
L R
L R
Input 2
Input 4
Input 1
Input 3
Input 5
Input 6
1 2
Model VI-6
-
+
-
+
-
+
-
+
-
+
Control Inputs
Device ID
MSB LSB
GND
BIAMP SYSTEMS
Designed in Australia
Assembled in USA
YEL:in use/conductor
GRN:link/act
CobraNet
®
PoE IEEE 802.3af
Class 0
N24138
Network
Connection
Device ID
Plug-in Barrier
Strip Analog
Inputs
Control
Inputs
RCA
Inputs
Control
Outputs
Not Active
Left LED
Right LED
Description
None
None
No power or data connectivity. Please check the PoE network connection.
Green
None
Link established.
Green
Flashing
amber
Link established and CobraNet activity detected; the unit is acting as a CobraNet performer.
Flashing
green
Flashing
amber
Link established and CobraNet activity detected; the unit is operating as a CobraNet conductor.
Flashing
amber
Flashing
amber
CobraNet fault. Check cabling and configuration for errors.