Back-box installation – Biamp RP-S4 User Manual

Page 4

background image

Back-Box Installation







Remove the back-box from the front panel (controls). Route cables through a
‘knock-out’ hole on the rear of the back-box. Install the back-box in a wall or
panel, in the same orientation as any standard single-gang electrical box.

The mounting surface may be from 1/8” to 1” thick.

(3.175mm to 25.4mm)

The mounting cavity must be exactly 3.6” high,

2.25” wide, and at least 2.75” deep.

(91.44mm H x 57.15mm W x 69.85mm D)


Insert the back-box into the wall or panel, then tighten the flange screws until
the flanges hold the box securely in place. Wire the remote panel pre-wired
pigtails to the appropriate cable conductors. Soldered connections with heat-
shrink insulation, or properly sized wire nuts, are recommended. Mount the
front panel to the back-box, being careful not to pinch or short the wires.
NOTE: When an RP-S4 is used with an RIK Remote Interface Kit, the RIK
circuit board will not fit inside the standard single-gang electrical back-box.
Therefore, the RIK must be installed external to the back-box (yet close enough
to be connected using the wire harnesses provided
). An alternative is to utilize
a double-wide electrical back-box, which has the additional space for an RIK.

Back-Box

flange

flange

knock-outs









RP-L1 & RP-L2 Block Diagram

25k

Ω

linear

GND C +10V

green

red

white

low (ccw)

wiper

high (cw)

cw

ccw

w

RP-S4 Block Diagram

DPDT

green

red

white

down (depressed)

wiper

up (released)

up
wiper
down

white

red

green

585.9131.90A

19Mar07

This manual is related to the following products: