beautypg.com

Flowline LD32‐S2_1 DeltaSpan User Manual

Page 4

background image

4 of 16 

MN301031 

Rev B 

DIMENSIONS 

Step Three 

Technology:    A  sealed  pressure  transmitter  is  placed  near  or  on  the  bottom  of  the  tank.    A  stainless  steel 
pressure  diaphragm  within  the  pressure  transmitter  is  exposed  on  one  side  to  the  application  liquid.    The 
other side is exposed to the reference pressure via a small ventilation tube located inside of the Polyurethane 
cable.    A  difference  in  pressure  between  liquid  and  reference  pressures  will  slightly  deflect  the  diaphragm.  
The  deflection  of  the  diaphragm  is  measured  by  a  built‐in  microprocessor  that  provides  greater  linearity 
correction over common thermal compensation methods.  A 4‐20 mA current signal proportional the height of 
the liquid is generated from the microprocessor.  

LD31 Series 

 

 LD32 Series 

 

 

Material Compatibility 

 The LD31 / LD32 series is made of 316 Stainless Steel (316 SS), 316L Stainless Steel (316L SS) with a 

cable  of  Polyurethane  or  Ethylene  Tetrafluoroethylene  (ETFE).      The  LD31  series  has  a  bullet  nose  of 
Polyvinyl Chloride (PVC).  

 Make  sure  that  the  switch  is  compatible  with  the  application  liquids.    To  determine  the  chemical 

compatibility  between  the  sensor  and  its  application  liquids,  refer  to  the  Compass  Corrosion  Guide, 
available from Compass Publications (858‐589‐9636). 

 

 