8
DTG 330
15/12/08 - 300011852-001-C
4. Operating the appliance
4.1.3
Control panel K3
1. General ON (1) / OFF (0) switch
2. Burner alarm indicator + Reset button
This light comes on when the safety control box is in safety
lockout (out of order).
3. Switch AUTO/
!
/TEST-STB
AUTO: This position enables automatic operation of the
installation in accordance with DIEMATIC-m 3 regulation
controls.
!
: The boiler no longer takes orders from the DIEMATIC-m 3
regulation into account. The boiler is regulated by the boiler
thermostat(s).
TEST-STB: Temporary action to test the safety thermostat
4. Safety thermostat with manual reset
Set at 110° C
5. Timed circuit breaker (4 A)
6. Pump shutdown switch
7. Boiler thermostat (30 to 90 °C)
8. Boiler thermometer
9. Switch for selecting the number of burner stages
(2-stage boilers)
10. Connector USB
4.2 Changing the settings
4.2.1
Control panel B3
Heating temperature setting: Set the boiler thermostat to the
desired setting.
Setting the domestic hot water temperature: Set the DHW
thermostat to the desired setting.