Omnireach, Ncx-1000, Large cabinet for fttn broadband service delivery – ADC OmniReach NCX-1000 User Manual
Page 3: Specifications

6/08
•
105052AE
OmniReach
®
NCX-1000
OmniReach
®
NCX-1000
Large Cabinet for FTTN Broadband Service Delivery
3
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
Cross Box
DLC Remote Cabinet
Cross Box
OmniReach NCX-1000
• Central location for xDSL service delivery
• LSA-PLUS IDC for distribution intercept
• “Look both ways” testing
• Integrated cable management
ComProtect
• Cross connect with
DSLAM circuit
protection
Adjunct DSLAM Cabinet
Specifications
GENERAL SPECIFICATIONS
Cabinet Size:
48" x 21" x 54" (height x depth x width)
OSP Pairs Termination:
710 connectors
DSLAM Pairs Termination:
710 connectors
Configurations:
FDI (1:2) protected
600 feeder pairs, 1,200 distribution
pairs, 432 DSLAM in/out ports
FDI (1:2) non-protected
900 feeder pairs, 1,350 to 1,800 distribution
pairs, 432 to 648 DSLAM in/out ports
DI (1:1) non-protected
1,600 OSP pairs in/out, 864 DSLAM ports in/out
MECHANICAL SPECIFICATIONS
OSP Input/Output:
LSA-PLUS Series 2 disconnect block (white)
DSLAM Input/Output:
LSA-PLUS Series 2 switching block (brown)
Contact Resistance:
< 1 m Ω
Insulation Resistance:
> 5 x 104 MΩ
Contact Material:
Copper Alloy
Contact Plating:
Silver
Number of Test Cord Insertions:
> 750
IDC Reterminations:
> 200
Cross Connect Wire Requirements:
24 AWG solid, tinned cross connect wire
for all terminations